Home |
Previous Page | Next Page Configuring and Monitoring Dynamic Server > Configuration Parameters >
- onconfig.std value
- 2000
- if not present
- UNIX: 1500 Windows: 500
- units
- Kilobytes
- range of values
- Minimum = 200
Maximum =(ROOTSIZE - PHYSFILE - 512 - (63 * ((pagesize)/1024)))
/ LOGFILES
The pagesize value is platform
dependent.
- takes effect
- When the database server is shut down and restarted. The size of log
files added after shared memory is initialized reflects the new value, but
the size of existing log files does not change.
- utilities
- onparams
See Change
Physical-Log Parameters.
- refer to
- The following topics in the IBM Informix Administrator's Guide:
- Size of the logical log and logging smart large objects, in the chapter
on the logical log
- Changes to LOGSIZE or LOGFILES, in the chapter on managing logical logs
- LTXHWM
LOGSIZE specifies the size that is used when logical-log
files are created. It does not change the size of existing logical-log files.
The total logical-log size is LOGSIZE * LOGFILES.
To verify the page size that the database server uses on your platform,
use one of the utilities listed in System Page
Size.
Home |
[ Top of Page | Previous Page | Next Page | Contents |