BAR_IDLE_TIMEOUT (XPS)

onconfig.std value
0
if value not present
0
units
Minutes
range of values
0 to unlimited
takes effect
When the database server starts

The BAR_IDLE_TIMEOUT configuration parameter determines the maximum amount of time in minutes that an onbar-worker process can be idle before it is shut down.

The BAR_IDLE_TIMEOUT configuration parameter is optional. If BAR_IDLE_TIMEOUT is set to 0, the onbar-worker processes never shut down until you shut down the database server.

You can set this option locally for individual storage managers to override the default or specified global setting.