Home |
Previous Page | Next Page Overview of the ON-Bar Backup and Restore System > Configuring the Storage Manager and ON-Bar >
Check the items in the following list to make sure that ON–Bar and
your storage manager are set up correctly:
- The storage manager is installed and configured to manage specific
storage devices.
- Make sure that the BAR_BSALIB_PATH configuration
parameter specifies correctly the XBSA shared
library or it is not set and the library is in the default location.
- Make sure that the BAR_BSALIB_PATH configuration
parameter specifies correctly the XBSA shared
library.
- The sm_versions file contains a row that
identifies the version number of the storage-manager-specific XBSA shared
library.
- The BAR_WORKER_MAX parameter is set
to a number greater than 0 in the storage-manager-specific section of the ONCONFIG file.
After you verify that ON–Bar and your storage manager are
set up correctly, run ON–Bar on your test database to make
sure that you can back up and restore data. For more information,
follow the instructions in Backing Up with ON-Bar.