Veritas Volume Manager

list controllers vxdmpadm listctlr all
list enclosures vxdmpadm listenclosure all
vxdmpadm listenclosure <enclosure>
Display Paths vxdmpadm getsubpaths ctlr=fscsi2
vxdmpadm getsubpaths dmpnodename=<enclosure>
Who controls the path vxdmpadm getdmpnode nodename=c3t2d0
vxdmpadm getdmpnode enclosure=<enclosure>
Controller (enable/disable) vxdmpadm disable ctlr=<controller>
vxdmpadm enable ctlr=<controller>
Statistics vxdmpadm iostat start
vxdmpadm iostat reset
vxdmpadm iostat show all
I/O balancing & load

vxdmpadm getattr enclosure <enclosure> iopolicy

vxdmpadm setattr enclosure <enclosure> iopolicy=<policy>

adaptive
priority
balanced (default)
round-robin
minimumq
single-active

Path Type

vxdmpadm setattr path <path-name> pathtype=<path-type>

active
nomanual
nopreffered
primary
secondary
standby

Displays the restore/error daemon vxdmpadm stat restored
vxdmpadm stat errord
Starts the restore daemon vxdmpadm start restored
Stops the restore daemon vxdmpadm stop restored