Informix Error -12003: Smart Large Objects: Cannot add entry to chunkadj table.
Cause and resolution
Smart Large Objects: Cannot add entry to chunkadj table.
Chunk with this number might already be in the table.
Oninit® Troubleshooting Guidance
Reasons / Common Causes
-12003 fires when the server can't add an entry to the internal chunkadj table — per the
official guidance.
- A chunk with this number possibly already being present in the table, per the official guidance — the named, likely cause.
Solutions / Resolution
- Check whether a chunk with this number already exists before retrying, per the official guidance's implication.
Examples
N/A
No specific triggering statement is documented beyond a duplicate/failed chunkadj table entry.
Diagnostic Checks
- Check the internal chunkadj table for an existing entry with this chunk number.
Related Errors / Related Topics
- -12011 — "Smart Large Objects: Cannot delete entry in chunkadj table." The
mirror-image operation on the same
chunkadjtable — delete rather than add.
Adding an entry to the chunkadj table failed, likely because that chunk number is already present — check for a duplicate entry.