Informix Error -12054: Smart Large Objects: Cannot open chunk adj partition.
Cause and resolution
Smart Large Objects: Cannot open chunk adj partition.
The chunk might be down.
Ensure that the smart-large-object space chunk is up.
Oninit® Troubleshooting Guidance
Reasons / Common Causes
-12054 fires when the chunk adjacency partition can't be opened — per the official guidance.
- The chunk being down, per the official guidance — the named, likely cause.
Solutions / Resolution
- Ensure the smart-large-object space chunk is up, per the official guidance.
Examples
Checking chunk status
$ onstat -d
Diagnostic Checks
- Check the chunk's online status, and bring it online if it's down.
Related Errors / Related Topics
- -12055 — "Smart Large Objects: Cannot open smart-large-object header partition." The same class of open failure, for the header partition rather than chunk adjacency.
The chunk adjacency partition couldn't be opened, likely because the chunk is down — check chunk status.