Informix Error -12067: Smart Large Objects Archive: Cannot extend pre-image temporary partition.
Cause and resolution
Smart Large Objects Archive: Cannot extend pre-image temporary partition.
An attempt to lengthen a temporary partition during an archive failed.
Ensure that the dbspace in which temporary partitions are placed is not full and is accessible.
Oninit® Troubleshooting Guidance
Reasons / Common Causes
-12067 fires when lengthening a temporary partition during a smart-large-object archive fails — per the official guidance.
- The dbspace holding temporary partitions being full or inaccessible, per the official guidance — the direct, only cause.
Solutions / Resolution
- Ensure the dbspace in which temporary partitions are placed is not full and is accessible, per the official guidance.
Examples
N/A
No specific triggering statement is documented beyond a full/inaccessible temp dbspace.
Diagnostic Checks
- Check the free space and accessibility of the temp-partition dbspace, and free up space or restore accessibility as needed.
Related Errors / Related Topics
- -12066 — "Smart Large Objects Archive: Cannot build pre-image temporary partition." The same class of temp-partition error, on building rather than extending.
- -12068 — "Smart Large Objects Archive: Cannot drop pre-image temporary partition during archive." The same class of temp-partition error, on dropping rather than extending.
The pre-image temporary partition couldn't be extended, likely due to a full/inaccessible temp dbspace — check both.