Informix Error -23566: CM error: Coserver counts are inconsistent, only the delete coserver command is allowed.
Cause and resolution
CM error: Coserver counts are inconsistent, only the delete coserver command is allowed.
The number of coservers specified in the $ONCONFIG file is less than the number of coservers that the database server discovered.
You must delete one of the coservers.
Oninit® Troubleshooting Guidance
Reasons / Common Causes
-23566 fires when the number of coservers in $ONCONFIG is less than the number the
database server actually discovered — per the official guidance.
$ONCONFIGspecifying fewer coservers than the server discovered, per the official guidance — the direct, only cause.
Solutions / Resolution
- Delete one of the extra coservers, per the official guidance — only the delete coserver command is allowed while this inconsistency exists.
Examples
N/A
No specific triggering statement is documented beyond a coserver-count mismatch.
Diagnostic Checks
- Compare the coserver count in
$ONCONFIGagainst the number the server discovered, and delete a coserver to reconcile them.
Related Errors / Related Topics
No closely related error codes are cross-referenced for -23566 in this set yet.
$ONCONFIG's coserver count was less than the discovered count — delete a coserver to
reconcile.