Informix Error -23620
Cause and resolution
Backup Manager Error: The supplied timestamp value disagrees with another existing value.
The point-in-time value for a logical restore is different than the point-in-time value of a restore that is currently active. Check currently active backup and restore operations using onstat -g bus and onstat -g bus_sm.
Oninit® Troubleshooting Guidance
Reasons / Common Causes
-23620 fires when a logical restore's point-in-time value differs from the point-in-time value of a currently active restore — per the official guidance.
- A point-in-time value that doesn't match an already-active restore's value, per the official guidance — the direct, only cause.
Solutions / Resolution
- Check currently active backup/restore operations via
onstat -g busandonstat -g bus_sm, per the official guidance, and reconcile the point-in-time values.
Examples
Checking active backup/restore operations
$ onstat -g bus
$ onstat -g bus_sm
Diagnostic Checks
- Run
onstat -g bus/onstat -g bus_smto identify the conflicting active restore's point-in-time value, and reconcile.
Related Errors / Related Topics
No closely related error codes are cross-referenced for -23620 in this set yet.
A logical restore's point-in-time value disagreed with an already-active restore's value
— check onstat -g bus/bus_sm.