Informix Error -23635
Cause and resolution
BACKUP Manager Error (23635)
The start_worker.sh shell script file in the etc sub-directory is missing or its execute permission is revoked. The Backup Manager cannot start a worker to process ON-Bar commands because it cannot execute the start_worker.sh file.
Make sure start_worker.sh exists and can be executed by informix or root.
Oninit® Troubleshooting Guidance
Reasons / Common Causes
-23635 fires when the start_worker.sh script in the etc subdirectory is missing or
its execute permission is revoked — per the official guidance, the Backup Manager can't
start a worker to process ON-Bar commands without it.
start_worker.shmissing, or not executable, per the official guidance — the direct, only cause.
Solutions / Resolution
- Make sure
start_worker.shexists and is executable byinformixorroot, per the official guidance.
Examples
Checking start_worker.sh
$ ls -l $INFORMIXDIR/etc/start_worker.sh
Diagnostic Checks
- Check
start_worker.sh's existence and execute permission in theetcsubdirectory, and restore it if missing or non-executable.
Related Errors / Related Topics
No closely related error codes are cross-referenced for -23635 in this set yet.
start_worker.sh was missing or not executable — the Backup Manager can't start a
worker without it.