Informix Error -23730: PLOAD (unload): conversion failure.
Cause and resolution
PLOAD (unload): conversion failure.
A conversion failure occurred when the database server tried to convert the data to ASCII or EBCDIC format.
Check that the external table columns have enough space reserved to write the ASCII or EBCDIC representation of the data and that the columns in the external table are compatible with the data selected.
Oninit® Troubleshooting Guidance
Reasons / Common Causes
-23730 fires when the database server fails to convert data to ASCII or EBCDIC format — per the official guidance.
- A conversion failure to ASCII/EBCDIC, per the official guidance — the direct, only cause.
Solutions / Resolution
- Check that external table columns have enough space reserved for the ASCII/EBCDIC representation, per the official guidance.
- Check that external table columns are compatible with the data selected, per the official guidance.
Examples
N/A
No specific triggering statement is documented beyond a data-conversion failure.
Diagnostic Checks
- Check the external table columns' declared width and type against the selected data, and widen/retype as needed.
Related Errors / Related Topics
- -23735 — "PLOAD conversion error: coserver-number, errno, filename." A related data-conversion error, on loading rather than unloading.
Converting data to ASCII/EBCDIC for unload failed — check external table column widths/types against the selected data.