Informix Error -23768: External table must be fixed format for external column type column-name.
Cause and resolution
External table must be fixed format for external column type column-name.
An external column type of PACKED, ZONED or BINARY was found for an external table that is not defined as a FIXED-format file.
Only FIXED-format files can define external-column types that are not CHAR.
Oninit® Troubleshooting Guidance
Reasons / Common Causes
-23768 fires when a column declares an external type of PACKED, ZONED, or BINARY
on a table that isn't FIXED-format — per the official guidance, only FIXED-format
files can define external-column types other than CHAR.
- A non-
CHARexternal column type on a non-FIXED-format table, per the official guidance — the direct, only cause.
Solutions / Resolution
- Define the table as
FIXED-format, or useCHARfor the column's external type, per the official guidance.
Examples
N/A
No specific triggering statement is documented beyond a non-CHAR type on a
non-FIXED table.
Diagnostic Checks
- Check the table's format and the flagged column's external type, and correct the mismatch.
Related Errors / Related Topics
- -23747 — "CREATE EXTERNAL TABLE: FIXED or DELIMITED columns must be external chars column-name." The related general rule this specific case reinforces.
A non-CHAR external column type was used on a non-FIXED-format table — use CHAR,
or make the table FIXED-format.