Informix Error -23773: Reached max error during load coserver-number, errno, filename.
Cause and resolution
Reached max error during load coserver-number, errno, filename.
When the database server tried to load the data from the external table, one of the coservers reached the MAXERRORS limit defined for the external table.
Oninit® Troubleshooting Guidance
Reasons / Common Causes
-23773 fires when a coserver reaches the MAXERRORS limit defined for an external
table during load — per the official guidance.
- A coserver hitting the external table's configured
MAXERRORSlimit, per the official guidance — the direct, only cause.
Solutions / Resolution
- Review and fix the source data's errors, or increase
MAXERRORSin the external table'sUSINGclause, per the official guidance's implication.
Examples
Increasing MAXERRORS
CREATE EXTERNAL TABLE ext_orders (...) USING (
DATAFILES ("DISK:1:/data/orders.unl"),
MAXERRORS 100
);
Diagnostic Checks
- Check the reject/log file for the specific rows that failed, and either fix
the source data or raise
MAXERRORS.
Related Errors / Related Topics
No closely related error codes are cross-referenced for -23773 in this set yet.
A coserver reached the external table's MAXERRORS limit during load — fix the source
data or raise the limit.