Informix Error -23915: Alter Fragment option not supported for hybrid fragmentation.
Cause and resolution
Alter Fragment option not supported for hybrid fragmentation.
The surviving table has hybrid fragmentation and an ALTER FRAGMENT ON TABLE option other than INIT, ATTACH, or DETACH was specified. INIT, ATTACH, and DETACH are the only supported options for hybrid-fragmented tables.
Oninit® Troubleshooting Guidance
Reasons / Common Causes
-23915 fires when ALTER FRAGMENT ON TABLE specifies an option other than INIT,
ATTACH, or DETACH against a hybrid-fragmented surviving table — per the official
guidance, those three are the only supported options for hybrid-fragmented tables.
- An
ALTER FRAGMENToption other thanINIT/ATTACH/DETACHon a hybrid-fragmented table, per the official guidance — the direct, only cause.
Solutions / Resolution
- Use only
INIT,ATTACH, orDETACHfor hybrid-fragmented tables, per the official guidance.
Examples
N/A
No specific triggering statement is documented beyond an unsupported
ALTER FRAGMENT option.
Diagnostic Checks
- Check the
ALTER FRAGMENT ON TABLEoption used, and confirm it'sINIT/ATTACH/DETACHfor a hybrid-fragmented table.
Related Errors / Related Topics
- -23908 — "Alter Fragment option not supported for hash fragmentation." The
equivalent restriction for hash-fragmented tables, which only support
INIT/ATTACH(notDETACH).
An ALTER FRAGMENT option other than INIT/ATTACH/DETACH was used on a
hybrid-fragmented table — only those three are supported.