Informix Error -23922: Serial column usage incompatible with fragmentation scheme.
Cause and resolution
Serial column usage incompatible with fragmentation scheme.
A table can be fragmented on a serial column only if the table is fragmented by hash and the serial column is the only column in the key. Tables fragmented by expression or hybrid that use serial columns in the fragmentation are not valid. Neither are hash-fragmented tables that have any columns in addition to the serial column used for fragmentation.
Oninit® Troubleshooting Guidance
Reasons / Common Causes
-23922 fires when a serial column is used in an unsupported fragmentation context — per the official guidance, a table can fragment on a serial column only if fragmented by hash with the serial column as the sole key column.
- A serial column used in expression or hybrid fragmentation, per the official guidance — the first named case.
- A hash-fragmented table with additional columns beyond the serial fragmentation column, per the official guidance — the second named case.
Solutions / Resolution
- Use hash fragmentation with only the serial column as the key, per the official guidance, if fragmenting on a serial column.
Examples
N/A
No specific triggering statement is documented beyond an unsupported serial-column fragmentation combination.
Diagnostic Checks
- Check the fragmentation scheme and key columns, and confirm a serial fragmentation column is used only with hash fragmentation and no other key columns.
Related Errors / Related Topics
No closely related error codes are cross-referenced for -23922 in this set yet.
A serial column was used in an unsupported fragmentation context — only hash fragmentation with the serial column as the sole key is valid.