Informix Error -25763: CICS Termination Code parameter is required for the CICS host environment.
Cause and resolution
CICS Termination Code parameter is required for the CICS host environment.
A termination code is required if you are using Answer/Extractor in CICS. Consult your Answer/Extractor DBA to find out the CICS termination code.
Oninit® Troubleshooting Guidance
Reasons / Common Causes
-25763 fires when Answer/Extractor is used under CICS but no CICS Termination Code was supplied — per the official guidance, a termination code is required in that environment.
- A missing CICS Termination Code when running under CICS, per the official guidance — the direct, only cause.
Solutions / Resolution
- Consult your Answer/Extractor DBA for the CICS termination code, and supply it, per the official guidance.
Examples
N/A
No specific triggering statement is documented beyond a missing CICS termination code.
Diagnostic Checks
- Check the SETUP screen's CICS Termination Code field, and obtain the correct value from the Answer/Extractor DBA if blank.
Related Errors / Related Topics
- -25762 — "CICS Paging Code parameter is required." A related CICS-parameter requirement, on the paging code rather than the termination code.
The CICS Termination Code parameter was missing — obtain it from the Answer/Extractor DBA.