Informix Error -25790: File name in SET EXPLAIN FILE or SET DEBUG FILE statement is too long.
Cause and resolution
File name in SET EXPLAIN FILE or SET DEBUG FILE statement is too long.
The file name provided in the SET EXPLAIN FILE or SET DEBUG FILE statement is longer than maximum allowed length of 256 bytes. Rename the file or store it in a directory with a shorter path.
Oninit® Troubleshooting Guidance
Reasons / Common Causes
-25790 fires when the file name in SET EXPLAIN FILE or SET DEBUG FILE exceeds 256
bytes — per the official guidance.
- A
SET EXPLAIN FILE/SET DEBUG FILEfile name longer than 256 bytes, per the official guidance — the direct, only cause.
Solutions / Resolution
- Rename the file, or store it in a directory with a shorter path, per the official guidance, so the full name stays within 256 bytes.
Examples
N/A
No specific triggering statement is documented beyond a file name exceeding 256 bytes.
Diagnostic Checks
- Check the full file-name/path length, and shorten it to 256 bytes or fewer.
Related Errors / Related Topics
- -25789 — "The file name in SET EXPLAIN FILE or SET DEBUG FILE must be a non-null
string." A related
SET EXPLAIN/SET DEBUG FILEerror, on a null/wrong-type file name rather than an oversized one.
SET EXPLAIN FILE/SET DEBUG FILE's file name exceeded 256 bytes — shorten the name or
its path.