Informix Error -4110: You cannot use more than one of the REPORT TO options in the OUTPUT section of a REPORT routine.
Cause and resolution
You cannot use more than one of the REPORT TO options in the OUTPUT section of a REPORT routine.
In this OUTPUT section, the statement REPORT TO appears more than once. Only one such specification is allowed. Remove all but one.
Oninit® Troubleshooting Guidance
Reasons / Common Causes
-4110 fires when a report's OUTPUT section includes more than one REPORT TO
specification — per the official guidance, only one is allowed.
- More than one
REPORT TOstatement in the sameOUTPUTsection, per the official guidance — the direct, only cause.
Solutions / Resolution
- Remove all but one
REPORT TOstatement, per the official guidance.
Examples
Duplicate REPORT TO statements
OUTPUT
REPORT TO PRINTER
REPORT TO "orders.out"
-- -4110: only one REPORT TO is allowed
Corrected
OUTPUT
REPORT TO PRINTER
Diagnostic Checks
- Check every report's
OUTPUTsection for more than oneREPORT TOstatement, and remove the duplicates.
Related Errors / Related Topics
No closely related error codes are cross-referenced for -4110 in this set yet.
A report's OUTPUT section has more than one REPORT TO statement — keep only one.