Informix Error -50089
Cause and resolution
In ixSuperTable::buildUpdateStr(), ixSuperTable::getDynKeyStr() returned NULL -- check to make sure a primary key was specified for some SuperField.
The ixSuperTable::buildUpdateStr() function is calling ixSuperTable::getDynKeyStr() in order to qualify which row to update. However, getDynKeyStr() is returning NULL. Check that a primary key was properly specified for the SuperFields in this SuperTable.
Oninit® Troubleshooting Guidance
Reasons / Common Causes
-50089 fires in the GUI builder ("Window Painter") class library -- per the official guidance: The ixSuperTable::buildUpdateStr() function is calling ixSuperTable::getDynKeyStr() in order to qualify which row to update. However, getDynKeyStr() is returning NULL. Check that a primary key was properly specified for the SuperFields in this SuperTable.
- In ixSuperTable::buildUpdateStr(), ixSuperTable::getDynKeyStr() returned NULL -- check to
make sure a primary key was specified for some SuperField -- an invalid argument, state,
or NULL value reaching
ixSuperTable::buildUpdateStr(), per the official guidance.
Solutions / Resolution
- Review the application's call to
ixSuperTable::buildUpdateStr()against the condition described above, and correct the argument, object state, or configuration involved, per the official guidance.
Examples
N/A
No specific triggering statement is documented beyond the GUI builder class library condition named in the official text.
Diagnostic Checks
- Check the application's use of
ixSuperTable::buildUpdateStr(), against the specific condition the official text describes.
Related Errors / Related Topics
No closely related error codes are cross-referenced for -50089 in this set yet.
In ixSuperTable::buildUpdateStr(), ixSuperTable::getDynKeyStr() returned NULL -- check to make sure a primary key was specified for some SuperField.