Informix Error -26365: Clustered FOT indexes are not supported.
Cause and resolution
Clustered FOT indexes are not supported.
FOT indexes must be non-clustered indexes.
Oninit® Troubleshooting Guidance
Reasons / Common Causes
-26365 fires when a forest-of-trees (FOT) index is defined as a clustered index — per the official guidance.
- The index is defined as a clustered index, per the official guidance — the direct, only cause; FOT indexes must be non-clustered.
Solutions / Resolution
- Define the index as non-clustered, per the official guidance.
Examples
N/A
No specific triggering statement is documented beyond a clustered FOT index definition.
Diagnostic Checks
- Check whether the FOT index is defined as clustered, and redefine it as non-clustered.
Related Errors / Related Topics
- -26363 — "FOT indexes cannot be functional indexes." A related FOT-index restriction, on functional indexes rather than clustering.
- -26364 — "Attached FOT indexes are not supported." A related FOT-index restriction, on attachment rather than clustering.
An FOT index was defined as clustered, which isn't supported — define it as non-clustered.