Informix Error -26382: CLOBDIR directory (%s) does not exist or is not accessible.
Cause and resolution
CLOBDIR directory (%s) does not exist or is not accessible.
The CLOBDIR value specified with the CREATE EXTERNAL or SELECT INTO EXTERNAL statement does not exist or is not accessible
Oninit® Troubleshooting Guidance
Reasons / Common Causes
-26382 fires when a CREATE EXTERNAL TABLE/SELECT INTO EXTERNAL's CLOBDIR value
doesn't exist or isn't accessible — per the official guidance.
- The specified
CLOBDIRdirectory doesn't exist, per the official guidance — the first named case. - The specified
CLOBDIRdirectory isn't accessible, per the official guidance — the second named case.
Solutions / Resolution
- Create the
CLOBDIRdirectory if it doesn't exist, and confirm it's accessible to the server process, per the official guidance.
Examples
N/A
No specific triggering statement is documented beyond an inaccessible/missing CLOBDIR.
Diagnostic Checks
- Check the
CLOBDIRpath's existence and permissions, and correct as needed.
Related Errors / Related Topics
- -26381 — "BLOBDIR directory (%s) does not exist or is not accessible." The same
class of directory-accessibility error, for
BLOBDIRrather thanCLOBDIR.
The CLOBDIR directory didn't exist or wasn't accessible — check its existence and
permissions.