Informix Error -26510: Cannot identify fact table
Cause and resolution
Cannot identify fact table
This query was not accelerated because the fact table cannot be identified. For outer joins, the fact table is the leftmost table in the query. For inner joins, the fact table is the table containing most rows.
Oninit® Troubleshooting Guidance
Reasons / Common Causes
-26510 fires when the optimizer can't identify a query's fact table for acceleration — per the official guidance.
- The fact table couldn't be identified, per the official guidance — for outer joins, the fact table is the leftmost table in the query; for inner joins, it's the table with the most rows.
Solutions / Resolution
- No action needed to "fix" this — per the official guidance, such a query runs on the database server instead; restructuring the join order/table choice may help if acceleration is desired.
Examples
N/A
No specific triggering statement is documented beyond an unidentifiable fact table.
Diagnostic Checks
- Check the query's join structure against the fact-table identification rule (leftmost for outer joins, most rows for inner joins), and restructure if acceleration is desired.
Related Errors / Related Topics
- -26515 — "Query does not contain a fact table of any data mart" A related offload-ineligibility diagnostic, on the identified fact table not matching any data mart rather than the fact table being unidentifiable at all.
A query wasn't accelerated because its fact table couldn't be identified — such queries run on the database server instead.