Oninit Logo
The Down System Specialists
+1-913-674-0360
+44-2081-337529
Partnerships Contact
Finderr

-1201 Number is too small for a DECIMAL data type.
-1202 An attempt was made to divide by zero.
-1203 Values used in a MATCH must both be type CHARACTER.
-1204 Invalid year in date.
-1205 Invalid month in date.
-1206 Invalid day in date.
-1207 Converted value does not fit into the allotted space.
-1208 There is no conversion from non-character values to character values.
-1209 Without any delimiters, this date must contain exactly 6 or 8 digits.
-1210 Date could not be converted to month/day/year format.
-1211 Out of memory.
-1212 Date conversion format must contain a month, day, and year component.
-1213 A character to numeric conversion process failed.
-1214 Value too large to fit in a SMALLINT.
-1215 Value too large to fit in an INTEGER.
-1216 Illegal exponent.
-1217 The format string is too large.
-1218 String to date conversion error.
-1219 Numeric value from database is too large for COBOL data item.
-1220 Numeric value from database is too small for COBOL data item.
-1221 Cannot convert null data types.
-1222 Value will not fit in a SMALLFLOAT.
-1223 Value will not fit in a FLOAT.
-1224 Invalid decimal number.
-1225 Column does not admit a NULL value.
-1226 Decimal or money value exceeds maximum precision.
-1227 Message file not found.
-1228 Message number not found in message file.
-1229 Incompatible message file.
-1230 Bad message file name formulation.
-1231 Cannot seek within message file.
-1232 Message buffer too small.
-1233 Invalid hour, minute, or second.
-1234 Function may be applied only to datetime data types.
-1235 Character host variable is too short for the data.
-1236 Bad era date.
-1237 Bad era name.
-1238 Bad era initialization.
-1239 Era year overflow.
-1250 Unable to create pipes.
-1251 Unable to create shared memory. semget failed.
-1252 Unable to create shared memory. shmget failed.
-1254 Unable to connect to remote host.
-1257 Operating system cannot fork process for back end.
-1258 Cannot attach to shared memory used to communicate with back end.
-1260 It is not possible to convert between the specified types.
-1261 Too many digits in the first field of datetime or interval.
-1262 Non-numeric character in datetime or interval.
-1263 A field in a datetime or interval is out of range or incorrect.
-1264 Extra characters at the end of a datetime or interval.
-1265 Overflow occurred on a datetime or interval operation.
-1266 Intervals or Datetimes are incompatible for the operation.
-1267 The result of a datetime computation is out of range.
-1268 Invalid datetime or interval qualifier.
-1269 Locator conversion error.
-1270 Interval literal may not have embedded minus sign.
-1271 Missing decimal point in datetime or interval fraction.
-1272 No input buffer has been specified.
-1273 Output buffer is NULL or too small to hold the result.
-1274 No output buffer has been specified.
-1275 Invalid field width or precision in datetime or interval format string.
-1276 Format conversion character not supported.
-1277 Input does not match format specification.
-1278 Invalid escape sequence.
-1279 Value exceeds string column length.
-1280 Library API incompatibility found in libgen.so.
-1281 Library API incompatibility found in libos.so.
-1282 Library API incompatibility found in libsql.so.
-1283 Library API incompatibility found in libgls.so.
-1284 Value will not fit in an INT8.
-1301 This value is not among the valid possibilities.
-1302 The two entries were not the same -- please try again.
-1303 You cannot use this editing feature because a picture exists.
-1304 Error in field.
-1305 This field requires an entered value.
-1306 Please type again for verification.
-1307 Cannot insert another row - the input array is full.
-1308 Cannot delete row - it has no data.
-1309 There are no more rows in the direction you are going.
-1310 Exiting the current function without executing a RETURN statement.
-1312 FORMS statement error number number.
-1313 SQL statement error number number.
-1314 Program stopped at statement, line number line.
-1315 4GL run-time error number number.
-1316 ISAM error number number.
-1317 A numeric conversion error has occurred due to incompatibility between a calling program and its function parameters or between a variable and its assigned expression.
-1318 A parameter count mismatch has occurred between the calling function and the called function.
-1319 The 4GL program has run out of runtime data space memory.
-1320 A function has not returned the correct number of values expected by the calling function.
-1321 A validation error has occurred as a result of the VALIDATE command.
-1322 A report output file cannot be opened.
-1323 A report output pipe cannot be opened.
-1324 A report output file cannot be written to.
-1326 An array variable has been referenced outside of its specified dimensions.
-1327 An insert statement could not be prepared for inserting rows into a temporary table used for a report.
-1328 A temporary table needed for a report could not be created in the selected database. The user must have permission to create tables in the selected database.
-1329 A database index could not be created for a temporary database table needed for a report.
-1330 A row could not be inserted into a temporary report table.
-1331 A row could not be fetched from a temporary report table.
-1332 A character variable has referenced subscripts that are out of range.
-1333 Strings of length > 512 cannot be returned from function calls.
-1334 The 4GL program cannot allocate any more space for temporary string storage.
-1335 A report is accepting output or being finished before it has been started.
-1336 Module name in the pcode file contains pcode version compile-version. This program can run pcode version runner-version. Run the pcode compiler with the -V option to check the pcode version that it produces. Then recompile all modules of your program, and run it again.
-1337 The variable name has been redefined with a different type or length.
-1338 The function name has not been defined in any module in the program.
-1339 Global variable name cannot be found in the descriptor table.
-1340 The error log has not been started.
-1343 No help file specified.
-1344 INFORMIX-4GL Run Time Facility.
-1345 Undefined opcode.
-1346 Number is too large for a DECIMAL data type.
-1347 Number is too small for a DECIMAL data type.
-1348 An attempt was made to divide by zero.
-1349 Character to numeric conversion error.
-1350 It is not possible to convert between the specified types.
-1351 The function (or report) name has already been defined. Function and report cannot both have the same name.
-1352 name may not be used as both a function (or report) name and a variable name.
-1353 Use '!' to edit TEXT and BYTE fields.
-1355 Cannot build temporary file.
-1356 Write error on temporary file filename.
-1357 Read error on temporary file filename.
-1358 Write error on TEXT or BYTE file filename.
-1359 Read error on TEXT or BYTE file filename.
-1360 No PROGRAM= clause for this field.
-1361 Illegal TEXT or BYTE file name. Null names are not permitted.
-1362 4GL runtime stack violation.
-1363 A fatal internal error has occurred - Application Terminating.
-1364 Error recovery setup failed - Application Terminating.
-1365 Application appname not found.
-1366 Unable to load application appname.
-1367 DLL dllname is not a resource DLL - Application Terminating.
-1371 The field fieldname does not exist in the current form.
-1372 The number entered is too large to fit in the decimal or money variable.
-1373 The field fieldname is not in the list of fields in the CONSTRUCT/INPUT statement.
-1374 SQL character truncation or transaction warning.
-1375 SQL NULL value in aggregate or mode ANSI database warning.
-1376 SQL, database server, or program variable mismatch warning.
-1377 SQL float-to-decimal conversion warning.
-1378 SQL non-ANSI extension warning.
-1379 Report functions may not be called directly. Please use the OUTPUT TO REPORT statement.
-1380 Only character expressions may be CLIPPED.
-1381 Cannot execute another runner when debugging.
-1390 The class "class" has not been defined in any module in the program.
-1391 Invalid class specified in AS clause.
-1392 Cannot use a NULL object.
-1393 The class class has already been defined.
-1394 Invalid ixRow object argument for built-in function.
-1396 A report PRINT FILE source file cannot be opened for reading.