Oninit® Archive
Results for “onstat -g cfg”
DB taking delay of 15 min to get connected.
Hi Edcel, Thank you for the swift response, could you please let me know where I can find the configuration parameter NS_CACHE ? Thanks, Siddharth…
Quickie question: Release 12.10: What is max size of physical log?
Hello Jacob, try onstat -g cfg full PHYSFILE to get the min/max values. The min Value is 200 and the max value is 2^31-1 kbyte (or 2TB-1kbyte). Cheers, Markus ------------------------------ Markus Holzbauer ------------------------------…
Informix 15.0.0.2 IL1: Insert from SMALL table into temp LARGE table very slow
Hi, Just a little update. The behavior we saw with temp dbspace/chunks after either - activating $ONCONFIG:TABLE_SIZE=LARGE and engine restart - onmode -wm TABLES_SIZE=LARGE seems merely a symptom not the cause. I shortened the time ranges a bit. So counters may differ from my la…
oncheck warning,What impact will it have on the future?
Ok, I make sense. Althrough I can't see that parameter in ONCONFIG, but it really exists with default value. ------------------------------ chuan lu ------------------------------…
Informix 14.10xc8 crash
Hello Garcia, Put it briefly, the SQL_DEF_CTR is an undocumented parameter. You are able to observe the real value on your system with 'onstat -g cfg full SQL_DEF_CTR'. I suppose if you set this parameter with this value '0x400000' (onmode -wf SQL_DEF_CTRL=0x400000), you can con…
Large memory segment vs smaller ones
No ONCONFIG changes are required. ------------------------------ Doug Lawry Oninit Consulting ------------------------------…
Changing DBSPACETEMP run-time
Hi, IBM Informix Dynamic Server Version 11.70.FC5XE Please, is there a way to change DBSPACETEMP for a session inside 4GL? ------------------------------ Sincerely, Dennis ------------------------------…
What prevents a RSS to roll forward as fast as its primary?
Hi David. You mean LOGBUFF rather than LTAPEBLK. See also: https://www.ibm.com/docs/en/informix-servers/14.10?topic=parameters-sec-dr-bufs-configuration-parameter ------------------------------ Doug Lawry Oninit Consulting ------------------------------…
restore through STDIO
HI, ifxclone can change the onconfig on the target instance E.g. it will turn off DIRECT_IO and can also change bufferpool entries! Regards, David. ------------------------------ David Williams ------------------------------…
Problems with temporary dbspaces
Hello, Change the DBSPACETEMP entry in onconfig file , separated them with semi colon (;), instead of comma (,). Rebounce ids, and see whether the error disappear. Hope it works -Fauziah-…
ontape does not finish the backup: tape full
TAPESIZE in the onconfig set to zero? Backups to disk running into a tape full and asking for a second tape should not happen. Hal Maner M Systems International, Inc.…
ontape error
Hi Sergio Your command syntax seems correct, so to me it implies it could be a Shell related issue. Split the work up into steps to see if it yields more information... [Pri]$ ontape -s -L 0 -F -t STDIO | ssh informix@<RSS IP or DNS name> "source ~informix/.bashrc; ontape -p -t …
Bizarre CM/Connectivity Issue on 12.10.FC14
One new item in the version, actually in FC13, is the sqlhosts cache, part of NS_CACHE config. It should be on by default, same 900 seconds as all the other 'name resolution' caches -> check 'onstat -g cfg [full] NS_CACHE' You might want to turn this off and see whether this make…
Strange message in online.log
Hi Snorri, this message can safely be ignored. Its main intent is to ensure a certain mini-feature (irrelevant to most) is configured equally on primary and all its secondaries - which it will be if you don't have this (intentionally undocumented) parameter in any of the server's…
fallocate function during create dbspace
I would like to ask additional questions. I know fallocate is a function only supported in Linux. Does the USE_FALLOCATE configuration parameter not apply to AIX? Since there is no test server in the AIX 7.2 environment, I cannot test its functionality. --------------------------…
RE: The rowid column does not exist in the user table.
onstat -g cfg full AUTOLOCATE You might inadvertently have got a (signle-fragment round-robin) fragmented table -> check 'oncheck -pt' or query systables/sysfragments for table in question. BR, Andreas ------------------------------ Andreas Legner ------------------------------…
ADO - activex data object
What do I require, to connect "ado activex data object" to Informix ? AIX 7.2 IBM Informix Dynamic Server Version 12.10.FC9W1 Regards Dirk…
Phys Log Size Inconsistency?
IDS 12.10.FC12 Solaris 10 1/13 I am working on a test platform, and, while importing a database, I'm getting messages in the online.log suggesting an increase in the physical log size. Here is an extract from the log: [BEGIN LOG EXTRACT] 09/05/19 10:57:14 Performance Advisory: …
PC_POOLSIZE?
Original post: IDS 12.10.FC12 Solaris 10 1/13 How does PC_POOLSIZE get changed? In our ONCONFIG file, the PC_POOLSIZE parameter is entered as: PC_POOLSIZE 127 The first few lines of 'onstat -g prc' are as follows: informix@ifmx-prod-anc>onstat -g prc|more IBM Informix Dynam…
Number of logical logs growing ?
I can't find any interesting info on logs, but decided to go in another way. I've removed 40 logs, stopped the db, cleared the logfile and started again. I'm now tracking when it will add a log ( in a script ) and tail the latest lines of log file ( ol_informix1210.log ) t try t…
RSS: Different # CPUs?
Those were my thought exactly. But, was uncertain whether RSS required identical settings in ONCONFIG as the primary. Thank you. DG…
listener-thread@soc_be.c:3073: err = -25582:
Adding Version details Informix Version : IBM Informix Dynamic Server Version 12.10.FC6 O/S Version : Red Hat Enterprise Linux Server release 6.9 Thanks & Regards, Karthik Rajan…
informixhq agent start problem
Here the informixhq-agent is trying to create a web socket to the informixhq-server. This is configured via the server.host and server.port parameters. This should be straightforward and will work if the informixhq-server is listening on this port, which it will be if it is runni…
onmode bug discovered (-wf)
Don't believe in a bug here. When starting the server he knows about the onconfig-file from the environment variable ONCONFIG. If you change this variable when the server is running it will not know the new value. Assuming that variable is only read once during the startup of th…
Continous logical log backup stuck - primary
Hi Marcus, yes, the the log backup is done in a directory, all the permissions are ok. It's the same as the other FC7 informix ha cluster that I configured beside few onconfig parameters, not related to backups. Thanks, Steven.…
SSC Configuration Parameters
What are the suggestible configurations values for below parameters in the OLTP environment with IDS 12.10 database running in windows server 2012R2 STMT_CACHE STMT_CACHE_HITS STMT_CACHE_SIZE STMT_CACHE_NOLIMIT STMT_CACHE_NUMPOOL…
High CPU IO Wait
Hello. Your engine configuration is pretty standard, so you are with a Ferrari, driving on a slow speed lane. You must tune it as soon as possible. Pretty sure you are missing buffers, so I would suggest you to tune then first if all. Several other parameters could bring you a gr…
Informix and speculative execution
Hi all, I have seen speculative execution patches for Firefox and SQL Server. Are there speculative execution patches for Informix in progress? There is no IBM Flash for Informix Dynamic Server and speculaative execution! Regards, David.…
storesdemo
see new AUTOLOCATE configuration parameter - in docs as well as in your onconfig.…
Rovoke insert permission but still can insert
I am doing it at the command line in the server directly in the directory C:\\\\Program Files\\\\IBM\\\\IBM Informix Dynamic Server\\\\11.50\\\\bin…
ROOTDBS file
I did not find the AUTOLOCATE parameter in onconfig file as well as onconfig.std file also. Im using IDS 12.10 FC8 version…
Update Statistics
what kind of things could I check in the onconfig file. They are working on getting me IBM technical support help, but that will be a few hours away.…
LTAPEDEV
You need to setup/verify that the alarmprogram (script/program defined in the parameter by that name) is configured to backup the logs. Each time there's a log switch the script/program will be called. Regards. On Tue, Apr 18, 2017 at 11:33 PM, BENJI LONG <ruggedmouse@hotmail.c…
Lots of SCHAPI errors
Sorry for the confusion.The upgrade I did is named "In-place migration", installed a newer version in another location, copied the configuration files, added or modified needed parameters and started the new instance.After the instance was started the database should be converted…
IDS 12.10 - Query Slow
Hi, I means value on onconfig 12.10 same or better than value onconfig IDS 11.10. i don't copy onconfig file and put on IDS 12.10. I already rebuild of your statistics is highly. We don't have performance issue for overall our system, only a few program, especially program runn…
Internal error in routine sqoptim
Hi, I cannot find MULTI_INDEX_SCAN on configuration file. It's new parameter need to add into our config file? Thank You…
OAT missing profiled fields.
What you are seeing - under Auto Checkpoints, 5 fields with descriptive names instead of acp_* - is the latest version of OAT. You are not missing anything. The article you referenced is very old (2008) and we actually made the change to use more descriptive names way back in 20…
IDS 12.10 onaudit configuration
HI, I want to enable audit configuration on production database, before that need some advice/best practices to avoid any degrade performance on my production database. 1. When we enable audit, any impact to performance.? if yes, how to minimize this. 2. how to configure audit…
IDS 12.10 on HP-UX- DS Total Memory
Hi, When we start Informix, we get this message, $oninit Warning: Parameter's user-configured value was adjusted. (DS_TOTAL_MEMORY) Need your opinion/advice for this, We need to adjust our memory parameter? Any explanation about this? Any document we can refer for this as refe…
ON-Bar database server is dismissing the logical
Thanks Art and Martin. IDS bounce worked as onconfig was changed for LTAPEDEV earlier. Thanks, ~ Pravin Bankar…
LOGBUFF size
Hi, We set , LOGBUFF 256 Occasionally, I still see this sometimes, 58087a28 Y--P--- 4082303 saapmgr - 551cf760 0 1 0 0 580882e8 G-BPX-- 3671545 saapmgr - 526d0898 0 2 29 48411 58088ba8 Y--P--- 2478091 saapmgr - 55a96230 0 1 116 14986 So, a session is waiting for the log buff…
DBSPACETEMP Parameter
Hi, The DBSPACETEMP Parameter in onconfig file create automatically the temporally dbspaces ? Or They must be created with onspaces utility. Thanks in advance.…
IDS 12.1- Query cost High
Hi, Based on our query cost ids 11.10 return 00:00:39 second and ids 12.10 return 05:34.13 second. A lot of different running on ids 11.10 and ids 12.10. I try found this parameter "OPT_SEEK_FACTOR" on onconfig file ids 12.10, but not exists. If we want add this parameter, what…
12.10.FC6 Mac port released
IBM Informix 12.10.FC6 release for Mac OS is officially available! John F. Miller III STSM, Lead Architect miller3@us.ibm.com 503-747-1366 IBM Informix Dynamic Server (IDS)…
new features about dynamic parameter added in 12.1
Cool, anyway, the real point is onmode doesn't do that in v12. Always forget about onstat -g cfg though, thanks. Art Art S. Kagel, President and Principal Consultant ASK Database Management www.askdbmgt.com Blog: http://informix-myview.blogspot.com/ Disclaimer: Please keep in…
oninit taking ages
Hi all, before I post a PMR: did anyone see an informix instance take 25mn to start ? 25 minutes was with 12.10FC4 on a linux/red hat VMWare (big server according to the vendors) With 12.10FC5W1, i had to wait 46 mn before deciding to kill oninit. I am using huge pages and RESI…
SDK degrades IDS
When Web Server connect With SDK client, the IDS degrade. I configure the NETTYPE soctcp,2,600,NET NETTYPE ipcshm,2,500,CPU I need know what happen and if I reconfigure another parameters…
BTS fails after ontape Restore
Hi Mark, Backup is done by 'ontape -s -L 0' Restore was done with 'ontape -r' No extra special parameters. And as I was typing this email, I was collecting the appropriate BTS-related lines from the 4 onconfig's in play (we use a special 'backup' onconfig for ontape). Lo and b…
Root db space fills up
as metioned above, maybe you need set TEMPTAB_NOLOG in you onconfig file…
Error Message in online.log file
Hi André. What setting do you have for ALRM_ALL_EVENTS in the $ONCONFIG file? I have found "alarmprogram.sh" can loop if set to 1. Regards, Doug Lawry…
RSS not working
Fee disk space on the chunk partition ok on the RSS server? Can you post your onconfig?…
Setup HDR
Sounds like the onconfig has the same STACKSIZE but what both servers read in at initialization is different. Bounce both servers and see if it's fixed.…
Physical Log size 2000 is too small
Hi, the onconfig we are using is from a inf version 9.7 wherein no PLOG_OVERFLOW_PATH located in it. I tried adding it to the onconfig and put a location but the inf instance when restarted still always fails. As for the onmode command we are always using onmode -ky maybe it's b…
ERROR doing ontape
Thanks for your response! So, is it possible to create a new dbspace then set it in $ONCONFIG and restart the instance? best regards…
virtual segment question
Did you try to increase the number of locks in the LOCKS parameter in Onconfig? Lloyd…
ontape error message
Increase the value of TAPESIZE parameter in onconfig and try the backup. Lloyd…
ROOTSIZE defaults
Configuration parameter ROOTSIZE in Informix v12.10.x defaults to 300000. This is different from our production version (11.70.x, HP-UX ia) where ROOTSIZE is 200000. I'm trying to understand the reasons for this size difference. The v12.x engine does come up with ROOTSIZE of 2000…
Onconfig name
Hi, I am developing a JDBC application, and need to read from within SQL the onconfig environment variable. From with IDS 11.70, I can extract the need information using the query: select trim(env_value) env_value from informix.sysenv where env_name = 'ONCONFIG'; The code nee…
Informix upgrade
Can we upgrade informix from Dynamic Server Version 11.70 to 12.1 workgroup edition directly?…
Problmes using ontape with an IBM TS2900 changer
The TAPEDEV section in the onconfig is as follow: TAPEDEV /dev/IBMTape0 TAPEBLK 512 TAPESIZE 0 We have played with the TAPEBLK from 512 to 4096 to no avail.…
when use IfxDataReader.GetIfxDateTime to NULL valu
Hello, The version of Informix products in my environment is: Database server: AIX IBM Informix Dynamic Server Version 10.00.FC5 IBM Informix CSDK Version 2.90 IBM-ESQL Version 2.90.FC4 Client: PC Windows IBM Informix-ESQL 3.70.TC5DE.…
How to set up temporary space per session
True, but I have noticed that you need register previously the temporary dbspace in onconfig file, I thought there was some way to make the settings "on the fly", by session. Roger…
recover SQLHOSTS file
Do the onconfig files also have that info?…
Auto Update Stats
Hi, I have one more query. I have the below entries in onconfig file for AUS AUTO_STAT_MODE 1 STATCHANGE 10 USTLOW_SAMPLE 0 Now all my tasks(mon_table_profile,Evaluator and Refresh) running fine at scheduled time. Now when I remove the above entries in onconfig file, still al…
DB_locale or local naming convention
Hi, I already mention the informix version. IBM Informix Dynamic Server Version 11.70.TC1IE…
Page size
Where do you set the page size when configuring Informix? I don't see it in the ONCONFIG anywhere.…
Re: manually edit onconfig?
You should never install the new version over the current one. If something goes wrong in the upgrade you'll have much more work to recover. Regards On Mon, Dec 17, 2012 at 6:38 PM, June Nebab LKINY <jnebab@gmail.com> wrote: > Planning an upgrade to 11.7UC6GE from 11.7UC5GE. I…
RE: manually edit onconfig?
I would give a try to the new onconfig_diff utility, it seems to help you identify and correct some of them.... Check it out! https://www.ibm.com/developerworks/mydeveloperworks/blogs/idsteam/entry/how_to_use_the_onconfig_comparison_tool_onconfig_diff3?lang=en Regards. Alexand…
Re: manually edit onconfig?
I'm a big fan of copying the current settings into the new ONCONFIG file. It gives you a good chance to see the new parameters, like those you mentioned - all of which were available in 11.70.xC5 BTW, so someone used an older ONCONFIG instead of editing the new one last time. By…
Re: manually edit onconfig?
Figure out what each of the new ones do, whether you want to use them or not, then add them to your old onconfig. Ideally on a test environment. j. On Dec 17, 2012, at 1:38 PM, June Nebab LKINY wrote: > Planning an upgrade to 11.7UC6GE from 11.7UC5GE. Installing new version o…
manually edit onconfig?
Planning an upgrade to 11.7UC6GE from 11.7UC5GE. Installing new version on same $INFORMIXDIR and on same server. I noticed new onconfig params (ie: AUTO_READAHEAD, NUMFDSERVERS, etc) that are in the UC6GE onconfig.std that are not in my $ONCONFIG. What is the proper way to dea…
Error -556 on @ reference
In IDS_A have a stored procedure do_some that has a insert into a local table. In IDS_B have a stored procedure do_some that does: call base@IDS_A:do_some(); Calling this sp works ok. In IDS_C i try to run: call base@IDS_B:do_some(); Fails with error -556 Cannot create, drop,…
Error # 40002
Also set AUTO_REPREPARE 1 in your $ONCONFIG file. Regards, Doug Lawry…
RTO_SERVER_RESTART configuration parameter
hello all we currently have this parameter disabled. I am looking for feedback on experiences using this parameter versus how we are doing it, which is to use the CKPTINTVL configuration parameter. thanks tom…
CPU informix
how to configure CPU with informix. For example, if i have 1 CPU with 4 cores and i want to assign only 2 cores. What is the correct parameter on onconfig file for this? Thank you for your answers.…
Re: help with informix on windows oncheck -pr erro
ok sounds like silly question but how do i find out what ONCONFIG variable is on windows ? which is likely to be correct set ONCONFIG=oncfg_apecert.0 ::set ONCONFIG=ONCONFIG.apecert…
doubt about parameters (PDQ)
Sorry people, I meant the MAX_PDQPRIORITY 100 onconfig parameter.…
doubt about parameters
I wonder what the ideal configuration for an IBM machine with 01TB P7-780 Ram for the parameters and PHYSBUFF and LOGBUFF with replication and without replication thank you very much Wanderlei - Intera Consultoria (55+11) 6707-3778…
IDS 7.31 UD5 data(base) recovery
Informix Dynamic Server Version 7.31.UD5 I understood that IDS 7.31 entered End Of Support in September 2009 ( 2 and a half years ago) I hope this is not a business critical system…
enterprise replication time to replicate data
IBM Informix Dynamic Server Version 11.50.FC6 Question for enterpise experts Does anyone know a command that will give me time that it takes to replicate data to a node? for example i update on server a and it replicates to server b . How long did it take? cdr view profile gives …
NOFUZZYCKPT: onconfig parameter or environment variable?
Is NOFUZZYCKPT an onconfig parameter or an environment variable? Is there any definitive documentation? Still running IDS 10 on Linux.…
Testing the 'free' versions - moving from Dev edition to Innovator-C
Art, thanks - I've gone for the separate INFORMIXDIR install (just had to change $INFORMIXDIR, $PATH and some paths in $ONCONFIG) and it's come up just fine.…
Spatial Data
hello reading thru the manual states that the ONCONFIG parameters for SBSPACENAME and SYSSBSPACENAME must be set for the default sbspace. We are running an HDR pair and have the parameters set on the Primary Server - does it also need to be set on the Secondary Instance ? thank…
Over 1,000 days of 24x7 database uptime!
On 29.07.2011 20:38 Lester Knutsen wrote: > From one of our customers, their Informix server hit 1,000 days today > .... congratulations;) > > IBM Informix Dynamic Server Version 10.00.FC8 -- On-Line -- Up > 1000 days 00:31:45 -- They beat mine just bit ... IBM Informix D…
IFX_FOLDVIEW
anyone experience any negative effects turning on this config parameter? thanks tom You can significantly improve the performance of a query that involves a view by enabling view folding with the IFX_FOLDVIEW configuration parameter. When the IFX_FOLDVIEW configuration paramete…
Setting up HDR- First Time -11.70 Innovator-C
Hi, I am setting up HDR for the first time. onstat - on primary shows IBM Informix Dynamic Server Version 11.70.UC2IE -- On-Line (Prim) -- Up 0:11:5s onstat - on secondry shows IBM Informix Dynamic Server Version 11.70.UC2IE -- Fast Recovery (Sec) -- Up 00s onstat -m on sec…
ISAM error 197: Partition recently appended to
Informix Dynamic Server Version 9.40.UC5 SUSE Linux Enterprise Server 10 (i586) I have done a level 0 backup directed to /dev/null and tried again. still it is throwing the same error.…
ontape -p/r with changed ROOTPATH
Jack Parker Wrote: ================================================================================ Not sure if you noted that you also need to change your $ONCONFIG = ROOTPATH to point to what is on the backup image. j. ==========================================================…
question about Query with joined view
Have you tried "IFX_FOLDVIEW 1" in your environment or $ONCONFIG file? Regards, Doug Lawry…
Tool to estimate the size of an index
Sorry, I forgot to provide the version of the installation: IBM Informix Dynamic Server Version 11.50.FC4 Operative System: AIX Version 6.1…
sqlerr:-243 and isam err:-111 in esql/c
This "may" be a good place for USELASTCOMMITTED set to all in the onconfig.…
Primary Slowness when RSS is active
You need to set LOG_STAGGING_DIR parameter in onconfig of the rss…
Can't access sysindexes remotely
Hi, We are using IBM Informix Dynamic Server Version 11.50.FC6 using Platform: SunOS 5.10 Generic_125100-09 sun4v sparc SUNW,Sun-Fire-T200 Thanks…
problem with onshowaudit
when i am using onshowaudit -l command its giving following error while onshowaudit -f /export/home/informix/aud/ids_mcp_qa2.2 is working fine onshowaudit -l ONSHOWAUDIT Secure Audit Utility INFORMIX-SQL Version 11.50.FC6W3 The directory name specified by the ADTPATH configurati…
Re: RE: new onconfig parameters added onconfig fil
Typically, I make a copy of the onconfig.std, naming it something like cheetah_online. Then I open up both the old and new onconfig, side by side, and copy from old to new. Obviously, the new onconfig has new params that were not addressed in the old onconfig and may have elimina…
Re: RE: new onconfig parameters added onconfig fil
Isn't that what I said? "If you simply just bring up the instance using your old onconfig, I believe that you will get whatever the default is for the new parameters, even though you do not mention them in your old ONCONFIG." -----Original Message----- From: ids-bounces@iiug.or…
new onconfig parameters added onconfig file 11.5
hello folks Can any one tell me at what stage the new onconfig parameters are added to the onconfig file when upgrading from 11.10 to 11.5. I have converted two instances from 11.10 to 11.50 One onconfig file has the new parameters at the end of the file the other doesnt have any…
Re: performance improvements for dbimport?
Thanks for all your valuable input. I changed some parameters now: 21:09:27 Onconfig parameter BUFFERPOOL modified from size=2K,buffers=262144,lrus=8,lru_min_dirty=5.0,lru_max_dirty=10.0 to size=2K,buffers=524288,lrus=8,lru_min_dirty=10.0,lru_max_dirty=50.0. 21:09:27 Onconfig p…
BACKUP_FILTER in onconfig
Hello, when I using BACKUP_FILTER in $ONCONFIG, parameter for "The tape block size, in KB, for backing up logical logs" is NOT LTAPEBLK, but it is TAPEBLK. Everything work fine (LTAPEBKL for logical log) when I turn off BACKUP_FILTER ... This is happening with ontape, with BAC…
garbage text in SHMNOACCESS parameter
On Jan 21, 8:15 am, Ian Michael Gumby <im_gu...@hotmail.com> wrote: > Just a guess. What's the hex value for that string? > grep ^SHMNOACCESS onconfig SHMNOACCESS �����������"������� grep ^SHMNOACCESS onconfig |cut -c17- �����������"������� grep ^SHMNOACCESS onconfig…
alarmprogram.sh
Good Morning My Informix dbs are all IDS 10FC4 and my alarm program in configure with the following parameter: ALRM_ATTENTION=3 In order to identify an issue the Im having with some particular session that is causing a excess of additional shared memory segments I would like t…
HA (HDR) Configuration Parameter FAILOVER_CALLBACK
The definition of this parameter (from the Admin Reference Manual, page 1-74) states: "The database server executes the script specified by FAILOVER_CALLBACK when a database server transitions from a secondary server to a primary or standard server. Set FAILOVER_CALLBACK to the f…
Informix Dynamic Server Software Downloads
It appears IBM has cleverly hidden the IDS downloads again on the Passport Advantage Website, at least from my prying eyes. I can find the Solid DB and the DB2 links just fine. Does anyone out there in IIUG-land with a Passport Advantage account know where IBM has stashed the dow…
DYNAMIC_LOGS in ONCONFIG
Good afternoon, We occasionally have a programmer than needs a large amount of log space to move a very large table. Instead of fiddling with the HTXHWM and LTXEHWM in the ONCONFIG file, has anyone successfully setup DYNAMIC_LOGS with IDS 10.00 on HPUX? Where would the dynamic …
Unsufficient buffer size for error message
Hi Please check your online.log and check also your onconfig file. thanks.…
IDS 11.5 - Configuration Parameter (PHYSFILE) remo
Hello, The PHYSDBS was not found in the downloaded 'onconfig.std' for the IDS 11.5UC1 version. Can you confirm if the PHYSDBS has been removed? Thanks! Reyna _________________________________________________________ Reyna Sabina Phone: (305) 361-4324 NOAA/AOML/PHOD Fax: (305) 3…
Buffer Turnover Rate for IDS11.x
All: I was wondering if there is a way to calculate the BTR on an instance that has both 2k and 16k page sized dbspaces, with buffers defined with 2 of the new BUFFERPOOL configuration parameter. Yeah, I know, I'll standardize 16k pages soon enough... but in the meanwhile, since …
OPTCOMPIND and perl
Anyone know if I can change OPTCOMPIND after establishing a DB connection or does it need to be set before connecting? ta SLES10 SP1 IBM Informix Dynamic Server Version 10.00.UC5…
Lock mode
Is there a way to set "lock mode to wait" once for a program or does it need to be reset for every single session to the database? Is there a configuration parameter (on the database side) to set the lock mode to wait for all sessions coming to the database? Thanks ___________…
Connection manager parametrs
Thanks for that link it really helped alot. But it does not tell about the SLA_WORKER, can some tell howmany SLA_WORK would be appropriate for about 500 connection on average? Can we change the FOC parameter without restarting the connection manager? How can we configure the cmsm…
Informix Dynamic Server Scheduler question
Hi! I'm working on a project at my faculty. It's a java desktop application with an informix database. I have a problem using informix dynamic server scheduler. I have a particular table in my database. This table contains records that are inserted by the desktop aplication I'm …
IDS 9.40 End of Support Imminent
I have seen a number of posts on CDI recently related to IDS 9.40 As per the announcement on September 7th 2007, effective on the dates listed below, IBM will withdraw support from the following product releases licensed under the IBM International Program License Agreement: 9…
oninit fails reporting problem with DBSPACETEMP
But in my ONCONFIG file, i have mentioned the tape device as STDIO…
Changing TAPEDEV from script
sed -e 's/^TAPEDEV/TAPEDEV NEW-TAPEDEV/g' onconfig > onconfig.other export ONCONFIG=onconfig.other after finishing just set the ONCONFIG to your default and delete onconfig.other Sebastian…
DBSPACETEMP
I note in the IDS 11.5 infocenter: "The dbspaces that you list in the DBSPACETEMP configuration parameter must consist of chunks that are allocated as raw UNIX® devices." Looking back to the IDS 10.0 manuals I see the same single quote... (well hidden!) I also note that windows …
use stored proc that return multiple columns in a query
forgot to include version info: IBM Informix Dynamic Server Version 10.00.UC6W5 -- On-Line -- Up 207 days 22:14:39 -- 1441100 Kbytes…
installing informix dynamic server in linux
hi, I'm new to informix... I tried to install informix dynamic server(iif. 11.50.UC2E.Linux-RHEL4.tar) in my linux machine. I'm getting an error like this... One or more prerequisite system libraries are not installed on your computer. Install libpam.so.0, libncurses.so.5…
Meaning of DS_NONPDQ_QUERY_MEM
Dear All.... http://publib.boulder.ibm.com/infocenter/idshelp/v111/index.jsp I refered to this document of IDS 11.1 , and found the following statements: Use the DS_NONPDQ_QUERY_MEM configuration parameter to increase the amount of memory that is a available for a query that is…
Informix Dynamic Server v 11.50 Developer's Edition
Does everyone know that the Informix Dynamic Server Developer's Edition v11.50 that you can download from the IIUG Web site (www.iiug.org) is NOT timebombed, is completely and fully functional (including HDR, MACH11, ER etc.). Do you know that the only limitations on this versio…
Informix Dynamic Server v 11.50 Developer's Edition
Does everyone know that the Informix Dynamic Server Developer's Edition v11.50 that you can download from the IIUG Web site (www.iiug.org) is NOT timebombed, is completely and fully functional (including HDR, MACH11, ER etc.). Do you know that the only limitations on this versio…
CONFIGURATION ONAUDIT-IBM Informix Dynamic Server
Hello, I need to configure onaudit and onshowaudit able to register for each of the consultations that are made to the database, either through dbaccess, ODBC or another application. I've been reviewing the IBM Informix Trusted Facility Guide, but I was not working. What param…
How to use Informix Dynamic Server
I have installed trial version of "Informix IDS Dynamic Server Developer Edition 11.5 for Windows 2003, XP, Vista, 32bit Version 1150TC1DE". But i am new to informix. Can anyone explain how to use IDS in detail.…
solaris 10, kernel parameters for ids 9.40
Hi, I'm testing my instances in a server with solaris 10. I read release machine notes And it says: b) On Solaris 10, all System V IPC facilities are either automatically configured or can be controlled by resource controls. The following kernel parameters are either removed…
Re: onconfig recommendations
mosserp@wellsfargo.com wrote: >> mosserp@wellsfargo.com wrote: >> >>>>> RESIDENT 0 # Forced residency flag >>>>> >>>>> >>>> (Yes = 1, No = >>>> >>>> >>>>> >>>>> >>>>> >>>> Don't know HP model numbers, but it this is a PA-RISC machine, you >>>> almost have to …
RE: onconfig recommendations
> mosserp@wellsfargo.com wrote: > >>> RESIDENT 0 # Forced residency flag > >>> > >> (Yes = 1, No = > >> > >>> > >>> > >> Don't know HP model numbers, but it this is a PA-RISC machine, you > >> almost have to set RESIDENT to -1 to prevent poor performance > >>…
Re: onconfig recommendations
mosserp@wellsfargo.com wrote: >>> RESIDENT 0 # Forced residency flag >>> >> (Yes = 1, No = >> >>> >>> >> Don't know HP model numbers, but it this is a PA-RISC machine, you >> almost have to set RESIDENT to -1 to prevent poor performance >> due to the >> archi…
RE: onconfig recommendations
> > RESIDENT 0 # Forced residency flag > (Yes = 1, No = > > > Don't know HP model numbers, but it this is a PA-RISC machine, you > almost have to set RESIDENT to -1 to prevent poor performance > due to the > architectures restrictions of only four active shar…
What is IPA abbreviation ?
Hi all IBM INFORMIX DYNAMIC SERVER 10.00 PRODUCT RELEASE bug_number 168928 description WITH NON-DEFAULT PAGE SIZE AND ACTIVE IPA'S, TABLE LEVEL RESTORES FAIL product_code ONUTILS component_code ARCHECKR What is IPA ? Thanks…
Re: onconfig recommendations
On Jan 2, 11:09 pm, "Kennedy, Randy" <RKenn...@scottsdaleaz.gov> wrote: > Would like to receive some feedback on our onconfig setup for current > platform. This is the 3rd physical server that the database has moved > to and just want to ensure we are using the best settings for…
[Fwd: Re: onconfig recommendations]
Kennedy, Randy wrote: > Would like to receive some feedback on our onconfig setup for current > platform. This is the 3rd physical server that the database has moved > to and just want to ensure we are using the best settings for given > platform. > > Current Server: HP rp5405 …
Re: onconfig recommendations
On Jan 2, 11:09 pm, "Kennedy, Randy" <RKenn...@scottsdaleaz.gov> wrote: > Would like to receive some feedback on our onconfig setup for current > platform. This is the 3rd physical server that the database has moved > to and just want to ensure we are using the best settings for…
onconfig recommendations
Would like to receive some feedback on our onconfig setup for current platform. This is the 3rd physical server that the database has moved to and just want to ensure we are using the best settings for given platform. Current Server: HP rp5405 4-Way (650 MHz) with 8GB RAM. 1 …
Newbie question-please don't shoot me
I have a newbie question. Please pardon my lack of knowledge with this. I have a Unix server (HP) that houses 2 9.4 Informix database servers (IE: there are 2 separate onconfig files that have unique INFORMIXSERVER parm values). The informix engine stopped (I think because the un…
Informix onconfig file configuration
Hello, We recently moved from a quad proc (hyper threaded to 8), 8GB RAM to a 2 socket dual core, 16GB RAM server. In order to maximize the cores and RAM what entries need to be modified, if any? Thanks, Jared…
BAR_MAX_BACKUP and BAR_WORKER_MAX
What's the difference between BAR_MAX_BACKUP and BAR_WORKER_MAX. Both seem to be doing parallel/concurrent log backup. Which one should be specified in onconfig ?…
IIUG TV
Great job on the video work!! I look forward to seeing more! -t- -- -- Informix Dynamic Server Database Engine -- http://www.informix.com --…
Re: Digital UNIX V4.0F + 7.31.FD1 Performance
Thank you, today on evening we make this changes in $ONCONFIG, restart the machine and hope it works! Greetings from Austria…
Re: Informix beats Oracle
Mark Jamison wrote: > Hi t, > > I'm not Serge, but the answer to that is yes. > > As of 11.10, you can have pessimistic-locking, or optimistic locking. > > Entirely configurable at the instance level. > > The onconfig parameter is > > USELASTCOMMITTED > As I wrote answering to S…
Re: admin tools like PC client
Mike, What version of Informix are you using? Informix SE? Informix OnLine? Informix Dynamic Server? Most Informix versions these days come with a product call I-Connect that needs to be installed on the PC and rovides the Informix ODBC drivers.…
Error when initializing
06:36:20 IBM Informix Dynamic Server Version [b]10.00.UC6TL[\\b] I believe this is likelt ot be a new ish instance to a newish user of the software…
onconfig problem
when i try to initialize server using oninit following message appears on screen "ONCONFIG can only specify a simple filename whith no path components" plz do replay me how to solve this one…
Initializing rhead structure...oninit: DBSERVERNAME 'cfms' not in sqlhosts file or sqlhosts file contents are damaged.
"onconfig.std" is used as a template for creating configuration files. If you only have one informix instance the configuration file is typically called just "onconfig". There's an environment variable called "ONCONFIG" which points to the configuration. If not set informix will …
IDS on Solaris(spark server)Multiprocessor Setup
Hello All, I want to set up IDS 10.0(FC4)instance on Sun Spark server, which has one 24 core processor. So i am not sure how should i give the multiprocessor settings in the onconfig files parameters related to that instance. Please find below the parameters about which i need t…
problems with Informix dynamic server 9.4 @ WIndows 2003
I have problems with connecting the server. I use correct user/password to connect to the server, but the server do not known the server. I'm sure the user exist and is one of the user in Informix_Admin group. I have installed Informix dynamic server 9.4 in a windows xp system in…
FASTPOLL
I am going to turning on the FASTPOLL configuration parameter on our IDS 10.00.UC5 database. How do I monitor its performance? I can't seem to find and onstat command that helps. Thanks Peter…
RE: Listing all the tables in using a dbspace in Informix
> Make sure $INFORMIXDIR and $ONCONFIG are set and that you have > permissions with your login ID to access them. There is also system > tables that can give you this information. System tables which can list out all the tables in a particular dbspace ?…
Re: onconfig
Hello, apart from editing ONCONFIG directly, some parameters are dynamically changeable: Usage: onparams ... -m <param> <value> ... -m - Modify the value of one of the following configuration parameters: AFFAIL, AFCRASH, AFW…
RE: onconfig
I don't run onbar, but I suspect you're right. LTAPEDEV, etc. would also probably be in this group as well. Either way, restore the old onconfig and you're OK. It may be a good idea to check the permissions on the file before you're done, though... --EEM -----Original Me…
Re: onconfig
I think the onbar config parameters can be changed on the fly as well. ----- Original Message ----- From: "Everett Mills" <eemills@nationalbeef.com> To: <informix-list@iiug.org> Sent: Friday, February 09, 2007 11:45 AM Subject: RE: onconfig > Stan- > TAPEDEV, TAPEBLK and TAPESI…
RE: onconfig
Stan- TAPEDEV, TAPEBLK and TAPESIZE can be modified on the fly through onconfig. Restore your old onconfig and you should be fine. --EEM -----Original Message----- From: informix-list-bounces@iiug.org [mailto:informix-list-bounces@iiug.org] On Behalf Of Stan Sent: Friday, …
onconfig
Hello. What will happen when during work (online state) IDS unfortunately someone modify onconfig. Which paramaters takes effect immediately (without restrart IDS). Thanks in advance Stan…
Informix produces error -1263 after system time is changed
Also I forgot to mention that the onconfig USEOSTIME is set to 1 (gets time from the host)…
Re: infdump
couldn't we at least ask him for a tiny snippet of his online.log - maybe there's more wisdom in such file than you might imagine. Tip: set MSGPATH (in onconfig) to ... ... and don't forget to restart the engine ;-)…
HELP : All logical logs are FULL
Hi All Thanks for your response. I solved the "All logical logs are FULL" . I did the following : ShutdownServer : onmode -ky Change Onconfig : LTAPEDEV in the onconfig to /DEV/NULL Restart Server : oninit After RECOVERY : onmode -ky Change Onconfig : LTAPEDEV change…
Re: Performance tuning suggestions needed
On 1 Oct 2006 20:10:51 -0700, calyanram@hotmail.com wrote: >this my onconfig file. > ...onconfig file snipped... Please give us a bit more information. Hardware specs (number of CPUs, memory, OS. etc.) would be good . . . JWC…
SHMADD and EXTSHMADD
Hi, What is the difference between SHMADD and EXTSHMADD? We know the meaning of the SHMADD onconfig parameter. Thanks, Khaled Bentebal ConsultiX Email: khaled.bentebal@consult-ix.fr…
License Extension
Help.. I need a license extension for the IBM Informix Dynamic Server Version 10.00.FC3R1TL which I downloaded to do a evaluation. How can I get the license extened..my project is in the final stages .. Dhaya Commercial bank…
DBSPACETEMP
Hello All, Just a quick question for you to ponder. Is it possible to include random dbscpaces in the DBSPACETEMP parameter with the onconfig file to prevent space problems in the temp dbspace when creating indexes etc. on very large tables?…
Re: Security Vulnerabilities Addressed in Informix Dynamic Server
Clive Eisen wrote: > Ian Michael Gumby wrote: > > Yes the buffer overflow issues are a pain and frankly they shouldn't occur > > if IBM did formal code reviews. Or rather they should be caught and > > corrected prior to release. > > > > "Paul Watson" <paul@oninit.com> wrote in m…
Security Vulnerabilities Addressed in Informix Dynamic Server
Not sure if this has posted here or not but .... http://www-1.ibm.com/support/docview.wss?rs=630&context=SSGU8G&dc=D600&u id=swg21242921&loc=en_US&cs=UTF-8&lang=en Cheers Paul Paul Watson Tel: +44 1414161772 Mob: +44 7818003457 Web: www.oninit.com GO FURTHER with DB2 GET THER…
Re: ONCONFIG and AIX
Hi, I would enable KAIO, too. Apart from KAIO the B-Tree Scanner usually benefits from some configuration: >From my experience increasing threshold (default: 500) reduces I/O significantly, enabling range scans (rangesize=500), too. BTSCANNER num=1,prio=low,threshold=50…
RE: ONCONFIG and AIX
> -----Original Message----- > From: informix-list-bounces@iiug.org [mailto:informix-list- > bounces@iiug.org] On Behalf Of tomcaml@yahoo.com > Sent: Thursday, July 27, 2006 12:57 PM > To: informix-list@iiug.org > Subject: ONCONFIG and AIX > > Hello All, > > I am looking for feed…
ONCONFIG and AIX
Hello All, I am looking for feedback, comments, etc. We are currently on IDS 10.FC4 on HP-UX 11 - migrating to IDS 10.FC5 on AIX on an LPAR partition on the i595 I have gotten this message in the log while performing some loads/alter tables/indexes, etc in development phase.…
Parametro TXTIMEOUT
Hola, quisiera saber si alguno de ustedes me puede informar que quiere decir el parametro del onconfig TXTIMEOUT 0x12c, a cuantos segundos se refiere. Gracias de antemano. Salu2...…
IFX_FOLDVIEW
hello all, i am not finding much on this new configuration parameter - IFX_FOLDVIEW - maybe i am blind but i am not seeing it...? thanks for any help! Tom…
Initialising Informix
I am trying to initialize informix on a new server and I am getting this error. The server is HP UX 11.11 and Informix IDS 7.31 What could be the problem / This action will initialize Informix Dynamic Server; any existing Informix Dynamic Server databases will NOT be accessible …
Informix Connection From WIN CE.NET Emulator?
How do I connect to informix dynamic server from WIN CE.NET Emulator? Is there a WIN CE informix driver?…
Re: Table Editor for Multiplatforms
Enhancements in Version 4.3 ..... also supports the Informix Dynamic Server 9.x. http://www.ibm.com/software/data/db2imstools/db2tools/db2te/…
EXTSHMADD New shared memory parameter?
Hi family. In configuring a new server, I noticed a parameter I have not noticed before: EXTSHMADD I'm trying to figure out from the "Administrator's Reference" exactly what is the functional difference between SHMADD and EXTSHMADD. The text reads: EXTSHMADD specifies the size…
Can't INSERT blob into specific blob space using JDBC
I tried an example with 3.00.JC3 and it works fine without having a default SBSPACENAME in the onconfig file. VG.…
Fragmentation Elimination Problem
I am on version IBM Informix Dynamic Server Version 10.00.FC4.…
Re: Informix Dynamic Server 9.30 - Shared Memory
Ronald Schwingel wrote: > Can someone please tell me how much Shared Memory (gigabytes?) > Informix Dynamic Server 9.30 (32-bit version) for AIX 5L can use > before asserting with a Shared Memory access error? Can you provide > documentation that I can pass on also? It looked to…
RE: Informix Dynamic Server 9.30 - Shared Memory
First off you shouldn't be getting shared memory access errors. That sounds more like a bug that technical support should address. I wouldn't be surprised if your getting can't allocate additional shared memory segment messages. Informix 32-bit on AIX is a bitch. The problem …
Informix Dynamic Server 9.30 - Shared Memory
Can someone please tell me how much Shared Memory (gigabytes?) Informix Dynamic Server 9.30 (32-bit version) for AIX 5L can use before asserting with a Shared Memory access error? Can you provide documentation that I can pass on also? We are looking at providing one of cust…
create a DB on Linux
Hi! I have installed Informix dynamic server on Linux. Now I want to create a data base. What should I do? Thanks…
Re: flagship sunk
Funny I have been able to download IDS 10 for Solaris, Windows and Linux am I just smarter than everyone else? www.informix.com Support and downloads In the middle trials and betas Oh look Informix Dynamic Server (IDS) V10.0 easy!…
Re: Validating the 'SBSPACENAME' sblobspace
"Is a command-line call significantly different from file system access?" Well for SQL yes. In sysmaster.sysconfig there is a cf_effective column. This is the value in use by the database server NOW, this does not have to match the ONCONFIG value. You can change the onconfig …
Re: IDS 10 - documentation questions
Oops! I mean IBM Informix Dynamic Server Version 10.00.TC3ET Althought the release notes (idse_win_release_notes_10.0.html) start with:- "Release Notes for IBM Informix Dynamic Server Express Edition for Windows Platforms 10.00.TC3E, 1 July 2005 " so it is TC3E or TCE3T? and …
Re: Sql to concatenate multiple rows to a single row / column
Thank you SaltTan - it works beautifully. BTW, we have IBM Informix Dynamic Server Version 9.40.FC6.…
Long transaction aborted in Informix IDS 7.31
the specific onconfig variables to review are LTXHWM and LTXEHWM, howvere if you don't have enough logical logs configured to cope with the transaction these parameters will not help and you could end up in a bigger mess such that the transaction will NOt rollback and your server…
v 9 stopping
search for a dir called informix (assume you installed it there) in there you should have a subdir called etc in there you should find a file called onconfig.<informixserver> search for MSGPATH which has the name of your logfile Superboer.…
Excessive DNS activity from Informix
We're running 7.3.something on HP-UX and our network admin complains about excessive DNS traffic from all the Informix systems. The traffic is a DNS query about the user's login, and seems to occur multiple times while the user is logged in, perhaps once for each DB query. Is the…
Redirected restore failure
>From the backup and restore manual renaming chunks duing a restore..key considerations... "During a cold restore, ontape performs the following validations to rename chunks: 3. If renaming the primary root or mirror root chunk, it updates the ONCONFIG file parameters ROOTPATH…
hyperthreading and onconfig parameters
We are upgrading our database servers to HP ProLiant DL380 G4 two-way systems. This platform supports enabling or disabling "hyperthreading". (See, for example, http://sysadminforum.com/t36970.html.) With hyperthreading enabled, the OS (Solaris 9, x86) sees 2 logical processors …
New IDS Forum on IBM Developerworks website
This forum provides a place for Informix Dynamic Server developers and users to share their questions, thoughts, and ideas with others. http://www-128.ibm.com/developerworks/forums/dw_forum.jsp?forum=548&cat=19…
Re: Problem with SE 7.25TC3 for Windows
Christian Knappke <chknews@gmx.net> schrieb: >It's *not* the OS parameters, but those of the Informix. >Please read the manuals for the parameter "LOCKS" and check if you >have only 250-something defined in SE's config file. Which config file? We are talking about SE and NOT ab…
RE: recording ONCONFIG changes
Tripwire or AIDE would do the trick too. -----Original Message----- From: owner-informix-list@iiug.org [mailto:owner-informix-list@iiug.org] On Behalf Of Jonathan Leffler Sent: Thursday, July 07, 2005 2:16 AM To: informix-list@iiug.org Subject: Re: recording ONCONFIG changes mw…
Re: recording ONCONFIG changes
mweallans@panacea.co.uk wrote: > Scanning the old messages I came across a "suspicion" from Neil Truby > that IDS 9.2 was't recording all changes to ONCONFIG in the message > log. > I've recently spent many days trying to find why a problem had recurred > and eventually I discove…
recording ONCONFIG changes
Scanning the old messages I came across a "suspicion" from Neil Truby that IDS 9.2 was't recording all changes to ONCONFIG in the message log. I've recently spent many days trying to find why a problem had recurred and eventually I discovered that it was because a previous change…
Re: ONCONFIG - comments
Juan Pablo wrote: My comments below: > Hi: > Let me begin by saying thanks to all of the frequent posters to this group. > I wanted to offer my config for comments. > thanks > ============================================================ > Hola: > Muchas gracias por el tiem…
Re: ONCONFIG - comments
"Juan Pablo" <in4mixperu@hotmail.com> wrote in message news:1120173312.07d6de6c2486de67e3cad47cd40e6341@teranews... > > Hi: > Let me begin by saying thanks to all of the frequent posters to this > group. > I wanted to offer my config for comments. > thanks > ====================…
Re: ONCONFIG - comments
Juan Pablo said: > > Hi: > Let me begin by saying thanks to all of the frequent posters to this > group. > I wanted to offer my config for comments. > thanks > ============================================================ > Hola: > Muchas gracias por el tiempo y su ayuda. Est…
ONCONFIG - comments
Hi: Let me begin by saying thanks to all of the frequent posters to this group. I wanted to offer my config for comments. thanks ============================================================ Hola: Muchas gracias por el tiempo y su ayuda. Estoy dejando mi archivo ONCONFIG para pode…
ONCONFIG - comments
Hi: Let me begin by saying thanks to all of the frequent posters to this group. I wanted to offer my config for comments. thanks ============================================================ Hola: Muchas gracias por el tiempo y su ayuda. Estoy dejando mi archivo ONCONFIG para…
Re: IDS 10 Express Edition
Note 10.00.xC3 = Enterprise Version 10.00.xC3E = Express Edition http://publib.boulder.ibm.com/infocenter/ids9help/index.jsp?topic=/com.ibm.relnotes.doc/uc3E/idse_win_release_notes_10.0.html Then click on "IBM Informix Dynamic Server Express Edition" in the right pane:…
setup Informix Dynamic Server Version 9.40.UC1E1 to linux error
I setup Informix Dynamic Server Version 9.40.UC1E1 to linux execcute oninit -ivy is failed the online.log is write /// 16:31:32 Dynamically allocated new virtual shared memory segment (size 8192KB) 16:31:32 Informix Dynamic Server Version 9.40.UC1E1 Software Serial Number AA…
ONCONFIG comments
Hi: Let me begin by saying thanks to all of the frequent posters to this group. I wanted to offer my config for comments. thanks ============================================================ Hola: Muchas gracias por el tiempo y su ayuda. Estoy dejando mi archivo ONCONFIG para pod…
ONCONFIG comments
Hi: Let me begin by saying thanks to all of the frequent posters to this group. I wanted to offer my config for comments. thanks ============================================================ Hola: Muchas gracias por el tiempo y su ayuda. Estoy dejando mi archivo ONCONFIG par…
RE: New installation
Yes I agree with Brian, you put something in the onconfig that required 161MB but you have defined the root dbs size 60MB that is not enought to cover all the requests. Check the PHYSFILE, LOGFILES LOGSIZE in the ONCONFIG file. If you need more help give us the full ONCONFIG. b…
Help with ONCONFIG needed
Having a problem with a client connection to an informix database. The server has two databases, db1 and db2. Each database has a separate ONCONFIG file which lists the different db names in them. ONCONFIG_db1 includes db1,but not db2 in the DBSERVERNAME/DBSERVERALIAS …
Informix Dynamic Server information Centre
Great new utility just posted under IDS 10 on the docs site has uses for other products and versions than just IDS 10 so take a look even if you are not using 10 yet!! http://publib.boulder.ibm.com/infocenter/ids9help/index.jsp…
The onconfig FILLFACTOR
My day for asking questions ... but that is how one gains knowledge :) The lead DBA for the company for which I am now working for as a consultant wants to establish an initial FILLFACTOR of 100 for those indices that represent a serial column. Since none of the tables having a…
Cannot find message file. Check INFORMIXDIR and DBLANG.
im trying to run the oninit -i in the command prompt when the message appear... we installed... IBM Informix Dynamic Server 9.40 IBM INFORMIX-4GL Rapid Development System Version 7.32.UC2 IBM INFORMIX-4GL Version 7.32.UC2 set up sqlhosts, services, onconfig, path... but when tr…
Configuration Parameters - Spreadsheet
Hi Everyone, I started to put together a spreadsheet that would calculate onconfig parameters based on a given set of values - such as memory, # cpus, # users etc etc. But, before I re-invent the wheel, I thought I would ask if anyone has such a spreadsheet or if one is availabl…
question about pdq memory
If you have a certain amount of memory configured in the DS_TOTAL_MEMORY parameter in onconfig, does that mean your engine reserves that memory only for pdq queries where you have pdqpriority set ? In other words, if you are not running any queries with pdqpriority set, is that m…
chunk capacity
we are using BM Informix Dynamic Server Version 9.40.UC2X3 on Linux Kernel 2.4.21 the command 'onstat -d' shows ... Expanded chunk capacity mode: disabled how can I change this mode to 'enabled'?…
IDS V7.30 and Windows 2000
Can Informix Dynamic Server Version 7.30.TC6 be run on a Windows 2000 host system? TIA Erwin…
Re: Error Initialize Informix Dynamic Server
Art S. Kagel wrote: > On Wed, 04 Aug 2004 05:05:41 -0400, madiego wrote: >>I install Informix Dynamic Server and when I initialize 'oninit -iv' : >> >>This action will initialize Informix Dynamic Server; any existing Informix >>Dynamic Server databases will NOT be accessible - Do…
Error Initialize Informix Dynamic Server
Hello, I install Informix Dynamic Server and when I initialize 'oninit -iv' : This action will initialize Informix Dynamic Server; any existing Informix Dynamic Server databases will NOT be accessible - Do you wish to continue (y/n)? y Checking group membership to determine ser…
RE: parametros ONCONFIG
Los parametros del ONCONFIG que tienes que setear para inicializar tu instancia como MINIMO son: ROOTPATH Path completo del chunk creado para almacenar el root Dbspace ROOTSIZE Tama�o del chunk en Kbytes (Ejemplo: 2048000 # 2Gb) DBSERVERNAME Nombre l�gico del server.(Eje…
parametros ONCONFIG
Me podrian ayudar con los parametros del ONCONFIG. No las tengo muy clara cada parametro, por lo que la misma me trae problemas para el momento que quiero OPTIMIZAR el servidor de bases de datos. Si alguien me puede ayudar a conocer mejor cada uno de estos parametros .... les agr…
Re: Informix Dynamic Server and DB Tuning
I am experiencing similar problems with users migrating from Standard Engine to IDS 9.30. It appears that some applications are more susceptible than others. What application(s) are you running? We also have experience of adding more BUFFERS, LOCKS, etc and not improving the sit…
RE: Informix Dynamic Server and DB Tuning
Muthana Increase BUFFERS in onconfig file. UPDATE STATISTICS for each table (as a minimum) rerun the query and see what improvements you get. If you still have problems post the results of:- onstat -p onstat -m onstat -R and sqexplain.out of any particularly slow query or updat…
Informix Dynamic Server and DB Tuning
Dear Sir, The question how can make DB Tuning for Informix Dynamic Server version 9:30 to get the query faster. I used IDS 9:30 and it's not quick enough like our old Standard Engine. which Parameter can i change to make that or what shall i do? Regards Muthana AL-Temimi…
Can IDS accessing Informix SE Tables.
Hello, Now we are using Informix SE. We are planning to go Infomix Dynamic Server 9.x. Before migrating our current applications to IDS 9.x., first we have to develop a new application in IDS 9.x, in that we need to use some of the tables from informx SE. Could you please answer…
onconfig for analisis
Hi, I post the onconfig file for its analisis: Operating System: SuSE 9.0 RAM: 1024 Mb Informix version: 9.40 UC2 All chunks are raw devices. Thanks. #************************************************************************** # # INFORMIX SOFTWARE, INC. # # Title: onconfig…
ONCONFIG for 9.40 offered for comment
9.40 FC3W2 on HP-UX 11.11 The server has 6 cpus and 6G of RAM. 3 other, small, IDS 9.40 instances run on the server, and one small 7.31. kaio is enabled. Just put 9.40 live, and it's running about 5-10% more slowly on some key processes. This reflects what happened in testing. …
Re: OnConfig parameters tuning
Laverio wrote: > Hi guys, I'm trying to speed up an IDS 9.30 on a Sun 7.5 system w/ > 2Gb ram and 4 processors that seems very slow on a large sequential > write (I suppose that the problem resides in the dbspaces on > filesystem...). Any suggestion? The following is my standard…
Re: OnConfig parameters tuning
"Laverio" <laverioNO@z-1000.net> wrote in message news:cac7sg$e8v$1@newsreader.mailgate.org... > Hi guys, I'm trying to speed up an IDS 9.30 on a Sun 7.5 system w/ 2Gb ram > and 4 processors that seems very slow on a large sequential write (I suppose > that the problem resides in…
Re: OnConfig parameters tuning
Laverio wrote: > Hi guys, I'm trying to speed up an IDS 9.30 on a Sun 7.5 system w/ 2Gb ram > and 4 processors that seems very slow on a large sequential write (I suppose > that the problem resides in the dbspaces on filesystem...). Any suggestion? > > My onconfig it's set as fol…
OnConfig parameters tuning
Hi guys, I'm trying to speed up an IDS 9.30 on a Sun 7.5 system w/ 2Gb ram and 4 processors that seems very slow on a large sequential write (I suppose that the problem resides in the dbspaces on filesystem...). Any suggestion? My onconfig it's set as follow: # System Configura…
Howto for Onconfig
Hi everyone, This is probably a question which has been asked often. But I could not find proper documentation on how to calculate and set correct parameters for Onconfig. I understand this is a complex question. But are there any articles on this ? Maybe they covered the topic …
Dose anybody have the dbtop script in the Troubleshooting informix course?
Dears, I study the Troubleshooting ibm informix dynamic server course. At the module 4 exercise need the dbtop script. Dose anybody has this dbtop script and post for me? Thanks. Philip Yeh.…
Work group edition - Unlimited edition??
Taken from IBM web site:- =========================================================================== The following Informix Dynamic Server Workgroup Unlimited editions have been added to the IBM Data Management Gold Transaction Processing Bundle for SMB Unlimited: IBM Informix…
Re: [Informix Dynamic Server (IDS):] Digest 2671
For a course in the US, check out: http://www-306.ibm.com/services/learning/ites.wss?pageType=course_description&co urseCode=L1760&country=us&language=en (IBM course L1760). There is probably a similar course offered in Europe somewhere. Hope this helps. Kevin Doiron Toronto,…
SHARED MEMORY LIMIT
Is posible to use with informix of 32 bits more than 2GB of shared memory in a Linux Machine? The base address in onconfig is: SHMBASE 0x41000000 Thanks in advance,…
Re: Transaction support in informix dynamic server(IDS)
chaithra wrote: > i wanted to know, if in IDS we can get to know the status of a > transaction at any given time. or once any transaction commits or > rollsback we should be able to know the status. > is it possible through c++ interface provided by the IDS. I'm not quite s…
Transaction support in informix dynamic server(IDS)
hi all, i wanted to know, if in IDS we can get to know the status of a transaction at any given time. or once any transaction commits or rollsback we should be able to know the status. is it possible through c++ interface provided by the IDS. thanx in advace chaithra…
configure computer for using informix
what shell I do to make my computer work with informix. I have installed winXP on my computer, informix 4 i informix dynamic server? THANKS…
Where can I get the client API?
Hi, does anyone knows where to get the client API for Informix Dynamic Server 7.x? Perhaps we want to access the server via api directly. Kind regards, Joachim Engel.…
Informix optimizer
Hi, Does anyone know if the Informix Dynamic Server (7.31 or 9.4) database optimizer uses star schema optimizer techniques? Thank you, Tony…
Changing database local / dbexport tapesize
Hi, Did you change TAPESIZE on your onconfig file? That could be the restriction! REGARDS…
TRUNCATE TABLE command in 9.3?
I am aware that Informix Dynamic Server previously has not included the TRUNCATE TABLE command. Does anyone know if 9.3 or 9.4 include this command?…
Linux fgl_getenv
Informix Dynamic Server Version 9.30.UC3 on Linux. Do I have to do something before I can use the fgl_getenv call in a stored procedure? When I try I get 674: Routine (fgl_getenv) can not be resolved.…
Re: High lngspins - IDS 9.30 UC2
Art S. Kagel wrote: > > One thing we do to reduce/eliminate the possibility of the Clariion > internal queues backing up is to maximize the number of spindles in > use. IMM we configure 60 drives which as 5 RAID10 arrays of 5 pairs > and 10 hot spares. Then we plaid the 5 stripe…
Re: onconfig and sqlhosts
Hi Thomas. Administrator's Guide for Informix Dynamic Server, Version 7.3 http://www-3.ibm.com/software/data/informix/pubs/library/ids_73.html HTH. -- Tsutomu Ogiwara from Tokyo Japan. ICQ#:168106592 >From: Thomas Ronayne <trona@ameritech.net> >Reply-To: Thomas Ronayne <trona…
onconfig and sqlhosts
I've managed to blow away my installed Informix system and cannot for the life of me find the notes I had about onconfig and sqlhosts. It's version 7.30.UC5 running on Slackware 9.0 -- can someone point me at the right document in Answers for the appropriate settings? Thanks.…
SPINCNT configuration parameter in 5.10
Informix Version 5.10 Hardware: HP-K 4-way that was upgraded from a single cpu. OS: HP-UX 10.20 The application runs on the server and uses shared memory connections. I am working on cpu bottlenecks and I found the following. According to the book 'Informix Performance Tuning S…
migration
We're in the process of migrate from 7.3 (HP-UX 9000) to 9.x (IBM AIX). 2 questions: * which one is better to migrate 9.3 or 9.4? * and what is the configuration parameters to change? * or any other things we need to beware of? Thanks, Tah Davis…
Re: Onconfig file parameters
Sometimes even the ontape parameters (TAPEDEV, LTAPEDEV, TAPESIZE, etc.) are not dynamic. What you can do is change a parameter in the onconfig file and then dump out the reserve page that holds the onconfig parameters with: oncheck -pP 1 1 Hope this suggestion helps. Brice Av…
RE: Dynamic Server versus Universal Server ??
Originally, Version 7.x was called 'Informix Dynamic Server', Version 9.0x was called 'Universal server' Starting with 9.1, Universal server became 'Dynamic server with Universal data option'. With 9.2, new names 'Internet Foundation 2000 ' and 'Dynamic server 2000' ware given…
Informix Dynamic Server 2000 startup problem
Hi, While starting up informix in multi user mode , we wait for the database to come up by checking the onstat - o/p . But if the system is loaded, even after onstat shows status as online , the connection is rejected by the database . The wait loop that we do is as follow…
RE: HPL Unloading error [1467]
Here's my onconfig file SHMVIRTSIZE 147456 SHMADD 8192 SHMTOTAL 0…
why I can't see the output of "onstat -g wts"
test:/informix>onstat -g wst Informix Dynamic Server 2000 Version 9.21.FC7 -- On-Line -- Up 5 days 13:23:03 -- 11132960 Kbytes Wait statistics not enabled How to enable the wait statistics???…
informix SDK 2.81 ifxoledbc OLEDB and ADO
When Updating or deleting a non existing row in a table, the informix oledb provider produces an "UnSpecified error". Environment: Informix Dynamic Server 7.31 Informix SDK 2.81 ADO 2.6 Any help will be appreciated. Thanks in advance…
onconfig file
The system administrator at my current site thought he would be very clever and he linked the onconfig files to different directories using ln -s. We have now discovered that these links are being lost when we use onmonitor and replaced by a local file, but not when we use vi. I…
onaudit
hi, i'm trying to use audit on IDS. but every time i start audit with "onaudit -l 1" (for example), i have an error message: $ onaudit -l 1 Onaudit -- Audit Subsystem Configuration Utility Copyright (C) Informix Software, Inc., 1997 Cannot set audit configuration parameters. P…
Re: Bloody ERP schema
Hi everybody, Well, yesterday we have tested the recommended NETTYPE parameter on a hpux machine as it could be set on this one of course. That is to say: #NETTYPE ipcshm,2,200,CPU # Configure poll thread(s) for nettype NETTYPE ipcshm,5,80,CPU # Configure poll thread(s) for n…
MSGPATH file - can size be limited?
Is there some configuration parameter I'm missing that allows for limiting the size of the MSGPATH file (usually .../online.log)? I'd like a way to limit it to the last X days of information. Under normal circumstances (database running without problems), how fast does this fil…
What requires an IDS Linux?
Hello What requires an Informix Dynamic Server Linux a desktop and/or a network version of Linux? Thanks in advance Jacqueline Romero Miranda…
IDS 7.31.Txx Windows NT Alaramprogram
i have change the path in the onconfig-file and restart the server but the alarmprogram will not be start if a event (logs) a generated! thomas…
Informix v Oracle
Hi Is there a function in Informix Dynamic Server 2000 that is like Oracles CREATE SEQUENCE that uses NEXTVAL/CURVAL and %ROWCOUNT, ect? Thanks for all contributions Jordan jbruce@asaglobalserv.com…
Redbrick Memory Management & Statistics
Hi, How can I control the amount of shared memory redbrick uses? I can�t find any parameter in the configuration file. Another question: Is statistics automatically maintained in RedBrick? Is there some SQL command like "update statistics"? Thanks in advance …
Retrieving product name
Hi all, Is their a system table somewhere on an informix server that stores the product name. For example 'Select owner from systables where tabname = � VERSION� will return the version of the server. I would like to be able to tell if a server is a Universal server or a Dynamic …
Re: ONCONFIG History
put it under source code control? SCCS and RCS are free tools and dont take too much resources. HTH Sujit testNews <mtabunda@amellar.com> on 10/04/2000 09:05:30 PM Please respond to testNews <mtabunda@amellar.com> To: informix-list@iiug.org cc: Subject: ONCONFIG History I…
RE: ONCONFIG History
Look at your online message log onstat -c |grep MSG -----Original Message----- From: testNews [mailto:mtabunda@amellar.com] Sent: Wednesday, October 04, 2000 9:06 PM To: informix-list@iiug.org Subject: ONCONFIG History Is there a way to know/track the changes made to ONCONFIG …
RE: ONCONFIG History
Changes are recorded in the message log at startup. Wayne E. Martin Informix Database Administrator Kmart Corp. -----Original Message----- From: testNews [mailto:mtabunda@amellar.com] Sent: Thursday, October 05, 2000 12:06 AM To: informix-list@iiug.org Subject: ONCONFIG History…
ONCONFIG History
Is there a way to know/track the changes made to ONCONFIG files?…
IDS 7.3x on Win2000?
Does Informix Online Dynamic Server 7.3x runs on Windows 2000 (Professional)? Thanks for your help. Guy Dillen…
TBLSPACE_STATS
Hi, what is the meaning of TBLSPACE_STATS variable in onconfig file? thank in advance.…
kernel parameters
HIE "INFORMIXERS" My server is hanging and the error message is " too many open files" and I understand that this is done at Unix level . I am using Unix system V and Solaris how can I configure the kernel parameters?…
Query Optimization: Wrong execution plan?
Xavi Tarafa Mercader wrote: > Any suggestion about how to improve the query performance? Set OPTCOMPIND parameter ( in onconfig file ) to 0. > Xavi. Leonid.…
Informix & ODBC Setup
Hi All, Can Informix ODBC DSN read the configuration parameters from a file instead of Windows registry? If yes, how? Thanks, Nick.…
Re: How to search for a string in a TEXT field
Hi, :-( SELECT name, REPLACE(text,"ZNOTREADY","found") AS your_output FROM tablewithtextfield; Blobs are not allowed in this expression. I use Informix Dynamic Server Version 7.31.UC2A…
WSTATS and Performance
Hi, does anybody know the performance degradation by setting WSTATS 1 in the onconfig file? Is this 1%, 5% or 10% ??? TIA Ruediger Papke…
Create user in Informix Dynamic Server
Hello all I`m new in INS. Could you help me? I have Database server with one user Informix. How to create another user to Database?…
Informix ODS on Win 2000?
Does Informix Dynamic Server V7.31.TC5 for Intel Pentium Windows NT 4 also run on Windows 2000? Thanks for any help. Guy Dillen ITP…
informix newbie needs help - out of shared memory segments, check system SHMSEG
On Thu, 29 Jun 2000 12:56:22 GMT, mars1972@my-deja.com wrote: >SHMSEG is an OS level configuration parameter that limits the size of a >shared memory segment. Informix is telling you that it tried to start >up with a larger shared memory segment than the OS would allow. Check …
Re: SE- Read performance problems
Try with seipcpip, rather than setlitcp. If you don't need network, that is. >>> <liliano@my-deja.com> 06/02/00 01:28pm >>> Hi, Do you know any configuration parameters that improve performance for Informix SE SELECT/FETCH operations ? (I use ESQLC under Solaris7 x86) Can i inc…
SE- Read performance problems
Hi, Do you know any configuration parameters that improve performance for Informix SE SELECT/FETCH operations ? (I use ESQLC under Solaris7 x86) Can i increase buffers ? My configuration "setlitcp" is important for performance ? Thank you Liliano Sent via Deja.com http://www.d…
Informix cost???
Someone can said how much does Informix cost? I need to know: -Informix costs -cost for client Thanks very much. I need the last version of dynamic server for Unix. Ciao, Berna…
RE: Informix Dynamic Server V7.3 on SCO Open Server V5.04 installation problem
In article <8gt34o$a47$1@hfc.pacific.net.hk>, Webmaster <webmaster@hypercom.com.hk> writes >Hi Murray, > >Furthermore, I have may some parameters change in the kernel for the >semaphore setting and upgrade the system memory to 64M Ram, but still the >same error. > >Attached is th…
Replication
Hello everybody. I would like to know if it is possible to replicate an Informix database between a UNIX-based 7.32UC2 Informix Dynamic Server and an linux-based IDS2000 without problems. Thanks in advance. jhernandez@geuropa.com…
ODBC Installation Problems on Win98
Hi there, I'm still not successful in setting up the ODBC drivers from Informix. I've got the IDS 7.30 running on a linux box and a PC running Win98. When I use the Informix driver it reports the error "Unable to load translation DLL" after I configured the parameters for the d…
NETTYPE question
I have a question regarding the NETTYPE parameter. Which one of the following is more efficient? And does each configure communication parameters for 256 users? In other words, does the first NETTYPE parameter configure 4 poll threads of class CPU each capable of handling 64 u…
dynamic server with Informix distant database
We have this problem : - write of a html page (this pages will contain many many fields). - Receiving of the page data on a http server based on a M1 machine. - Using of 4gl/informix programs based on the M2 machine with the pages data - 4GL programs will set up a � result � tabl…
Problems with IDS 7.30.UC10-1 for Linux
Hi, how are the the described kernel parameters concerning the shared memory (in IDS_7.3) configured in Caldera Linux 2.3 ? Thanx, Andi…
HELP! Informix Dynamic Server 7.3
I'm trying to install a new IDS on Linux (RedHat 6.1) on a cooked file. Everything looks right, but upon oninit, I receive the following: oninit: Cannot open chunk '/u1/naf_chunk'. errno = 2 oninit: Fatal error in shared memory initialization Log reflects: 09:11:07 Informi…
UDR Support in Informix Dynamic Server.
Can someone tell me what exact version of Informix Dynamic Server that first supported C User Defined Routines. I've tried searching for this on their website with no joy. (their advanced search doesnt work at all !) Rgds, Peter. Sent via Deja.com http://www.deja.com/ Before y…
Re: Memory problems? Please help.
>>What is the connection type? shm or soc ? >> >What are these? See NETTYPE in your onconfig file. HTH Michael…
OFFICE Connect V.1
Informix Office Connect, Version 1.0, is compatible with the following Informix servers: Informix Dynamic Server, Version 7.3 or later Informix Dynamic Server with Universal Data Option, Version 9.14 Informix Dynamic Server 2000, Version 9.2 or later e Informix-SE 7.23 n�o func…
System catalogue
Hello! Can anybody explain me how I can create trigger on "informix".systables? (The server I deal with is Informix Online Dynamic Server 7.3.) Max…
datase connectivity problem
Christina Southam wrote: > > We have an application which connects from client pcs (using informix client > software) to an informix database (v7.22) running on SCO unix (v5.0.4.) > > Recently we have noticed that once we reach 109 connections to the database > any subsequent co…
Compatability between Informix products
Hi, I need some version compatability information for the following products. Hardware Platform: Hewlett Packard OS Platform: HP-UX version 10.20 Informix s/w: Informix Universal Server 9.20 Informix Dynamic Server 7.31 Informix Gateway to DRDA vers…
Re: Informix on SuSE Linux 6.2
In article <385FA8D4.5F3306F3@bloomberg.net>, kagel@bloomberg.net wrote: > [Earlier discussion SNIPPED] > > No. The ONCONFIG file parameter NETTYPE configures the listeners and > replaces the OL5.xx parameter USERS to configure the number of concurrent > users that can attach …
INFORMIX ONLINE startup time
In article <81c0al$6l7$1@scesie13.sie.siemens.at>, "Martin Sambor" <martin.sambor@siemens.at> wrote: > hello > > I want to know which parameter have influence at the startup time (normal > oninit, no oninit -i) from informix online (7.24 or higher). > Is this based only on the …
informix dynamic server on linux help
Hi all, I am an informix newbie, and i have problems running it on redhat linux 6.0. The installation went just fine, but now when i start dbaccess and try to create a new database i get this error message: 25584: Network driver can not access server program /opt/informix/lib/sq…
Informix Dynamic Server on IBM SSA
Can any one share their experiences, recommendations, pit-falls, comments about creating an IDS db engineOLTP environment on an IBM SSA Raid system? We have 2 SSA adapters and have 4 loops with 4 drives each. The IBM techs for the Smoothstart services will be coming next Tuesday…
Re: Dumb question
Sorry all, I think I found the answer to my own dumb question in the documentation (last place I would have thought to look). "The database server uses the ONCONFIG file during initialization" >Is it safe to edit my onconfig file when the database is live ? > >Or should I stop…
Please help me!
Hello! 1, Can somebody give me information, what is the new features for Version 7.24 of Informix Dynamic Server according to Version 7.20 of Informix Dynamic Server? 2, Are Version 7.20 of Informix Dynamic Server and 7.20 INFORMIX-ESQL/C 2000 Year Compatible? 3, W…
Re: installing Informix dynamic server
From: "Joerg_Mauz@abs.org" <Joerg_Mauz@abs.org> > Is there something wrong the the gateway, Hotmail or are there just loads of idiots posting today. (Apart from me, that is! :-) ______________________________________________________ Get Your Private, Free Email at http://www.hot…
installing Informix dynamic server
hi all, can anybody give me an URL where to find a good description of how to setup and install an Informix Dynamic Server with using RedHat Linux ??? I've searched a whole day but founf nothing useful.. :( thx ind advance joerg…
Help! Cant start database service
Hello All I had my informix dynamic server (7.3) running fine till a few days back. Now the dynamic server service and the informix messenger service won't start automatically and if I try to start the server, it does start but I'm unable to connect to it. If I try to start the…
Lock Table Overflow - onconfig
We get an error in the Informix log-file. Lock table overflow. What do we have to change in the onconfig-file ? Kind Regards, Franky Thiel franky.thiel@Infohos.be…
Setting up shared memory connection
Did you add the DBSERVERALIASES line in the onconfig file? -- James Edmiston Quest Information Systems, Inc. www.questisinc.com…
Informix Online Dynamic Server DBA Book
Hello Could anyone recommend a good Informix Online Dynamic Server book. I did a search in Amazon.com but I could not decide on which one to choose. Thanks in advance. Ajay…
Re: ontape in HP-UX
You need verify the sintax of onconfig file for this entries: TAPEDEV /dev/rmt/0m # Tape device path TAPEBLK 512 # Tape block size (Kbytes) TAPESIZE 7800000 # Maximum amount of data to put on tape (Kbytes) (This is my onconfig fil…
pricing for informix info?
Hello, Was wondering what other people out there paid for informix dynamic server 7.3... Basically, i wanted to know if they had a web server licensing schem like microsoft. or ibm's db2 (per cpu license). and would the licenses be transferable if I decided to move from le…
Re: Determining version dynamically
Hi, If you have Informix Dynamic Server then use the following sql-statement ' select DBINFO('version', 'full') from systables where tabid = 1' result from the sql is : Informix Dynamic Server Version 7.30.UC5 Take a look in Informix Guide to SQL: Syntax for more about DBINFO…
KAIO: out of OS resources error
Hi~ My informix dynamic server write "KAIO: out of OS resources error .." in online.log. This error log is written during ontape task. How can I solve this problem? platfom : SunOs 5.5.1 Informix Dynamic Server 7.24 uc6 Thanks.…
64bit IDS for Solaris 7/SPARC ?
Is there a 64bit Informix Dynamic Server 7.3x for Solaris 7/SPARC available? tia, joerg…
Posting from the Informix-list
what is the last version of Informix Dynamic Server for HP-UX 10.20, where can i find more Information about this.…
Latest versions for various Informix products ???
Which are the latest versions for Informix Dynamic Server Informix Dynamic Server, Workgroup Edition Informix 4GL Informix SQL on Solaris 7/SPARC ? Where can I find such informations on Informix's website ? tia, joerg…
cdr command line utility in informix 7.24
Hi, Is there a cdr command line utility in informix dynamic server 7.24? I tried to locate it, but the executable is nowhere to find. Thanks, Lu…
Problem Installing Informix Dynamic Server
I downloaded a Try&Buy version of Informix Dynamic Server V7.30 for NT. I installed it on an NT Server. The install seemed to go ok, but after a short time of investigating IECC, I got a blue screen. After this when I started the Command Center, a task seemed to start, but it w…
Re: DS_HASHPOOL and DS_HASHSIZE
kbg wrote: > > How do you configure DS_HASHPOOL and DS_HASHSIZE? > does these parameters exist on an IDS 9.14? That should be DS_HASHSIZE and DS_POOLSIZE (there was a typo in my article in TechNotes). DS_HASHSIZE is the number of hash list and must be a prime number. It default…
shared memory error SCO install
In article <3771800C.6FF8BF38@saw.net>, Brian Adams <adams@saw.net> writes: > Why are getting this error "Fatal error inshared memory creation" > > You have to set the kernel-parameters documented in $INFORMIXDIR/release/en_us/0333/IDS_7.3. I use this script: #!/bin/sh echo SHM…
Problems starting IDS 7.30.TC7 on Windows NT SP4.
When i try to start informix dynamic Server, the following message appears "Only informix user can start informix dynamic server" this message appears when i logged on with the informix's user. When i try to start the service on the control panel , error 2140 appears.…
shared memory question
Phillip Tien wrote: > > I have a configuration question on the onconfig file. I'm wanting to > change (increase) the number of BUFFERS and SHMVIRTSIZE on the instance > I'm running, but I'm wondering if I should be concerned with the Unix > memory configuration before doing so. …
Re: Informix 7.3 UC5 on RH Linux 5.2
Additional INFO: Please see attached "sqlhosts" and ONCONFIG files...…
Out of buffer?
Hi, I got the following error message from an Informix IDS 7.30: <<Informix Dynamic Server>>> WARNING! Buffer pool size may cause Dynamic Server to get into a locked state. Recommended minimum buffer pool size is 4 times maximum concurrent user thre…
Re: onconfig parameters
> onstat -c shows you the contents of the ONCONFIG file, but then so does vi > $INFORMIXDIR/etc/$ONCONFIG. Perhaps I did not understand the question? Does onstat -c reflect changes made by onmode commands? I should try that and see...that, to me, would be the compelling reason …
Re: onconfig parameters
Thomas onstat -c shows you the contents of the ONCONFIG file, but then so does vi $INFORMIXDIR/etc/$ONCONFIG. Perhaps I did not understand the question? HTH Sujit "Thomas G. Smith" <tsmith@wdn.com> on 04/28/99 12:19:10 PM Please respond to "Thomas G. Smith" <tsmith@wdn.com> …
onconfig parameters
Is there a command to force the engine to show me what all the onconfig parameters (and other perhaps unknown parameters) have been set to?…
Linux VS NT4.0
Hi, Is it true that Informix Dynamic Server workgroup edition 7.30 is ported for Linux, and if it is so does anyone can tell me what to chose between Linux and NT4.0 for running Informix Dynamic Server workgroup edition 7.30. Also I'd like to know for which version of Linux, Inf…
RE: How Do I determine the Max Users?
> I have the smae problem and question. > What do you mean with: "Look at the configuration and see how many users > it allows" ? WHERE DO I HAVE TO LOOK THAN ? I think that was the initial > question ? The question was vague, which is probably why Jonathan answered it the way h…
Starting Informix Dynamic Server !
Hi Gurus, Just wondering is there any difference in starting the informix engine as root user versus as Informix user. ? The reason why I ask this question is , the IDS 7.23 UC6 on HP-UX 10.2 crashes due to a bug (declared as bug by Informix Technical support)when we start in…
Informix Dynamic Server Archive/Restore
Hello All: We have a large scale Informix DB resident on an HP 9000, K460, with AutoRaid Disk Subsystem (218gb). And we are running IDS 7.30. Currently, we are using the Informix ontape archive/restore utility to archive the DB and to perform continuous logical logging. We u…
Any one know this?
Hi folks: Is there a script that can check informix on-line dynamic server is up and running or not? If not it will e-mail a note to D.B.A. groups Thanks in advance Garry…
onconfig tuning
Hi all! I have posted to the web my collection of notes on onconfig parameters. It is not yet complete but pretty far along. http://home.earthlink.net/~mildness/bamph/informix.htm It has helped me over the years to have this list in my PDA. If you think it useful feel free…
converting Informix Online 5.1 esql/c to Dynamic Server esql/c?
Hi converting Informix Online 5.1 esql/c to Dynamic Server esql/c? What is the easiest way to do this? Is there a parser that could do this? edward…
RAID Technolgy
We are using Informix Online Dynamic Server 7.2. We are going in for a new DEC UNIX Server with RAID Technolgy. It incorporates mirroring at the hardware level. So is it not necessary to do mirroring using Informix?. Can anybody give suggestions regarding mirroring and other feat…
Informix on Linux
Does anybody know how much a copy of Informix Dynamic Server would run me for use on Linux?? Thanks in advance -steve…
query maxed out problem.
Yan Zhu wrote: > > hi all: > > I am running informix 7.22 on solaris 2.6. > I wrote a web interface for the user to construct sql statement, > then I save it to a sql file, and call dbaccess to execute it. I just > found out that if I submit the query very quickly, say 50…
Upgrade Dynamic Server 7.13 - 7.24
I need to upgrade Informix Dynamic Server version 7.13 to version 7.24. Can anyone advise of any problems they may have had whilst doing this?…
Regarding calling an INFORMIX procedure from a UNIX shell script
I use dbaccess for this purpose. Syntax is "dbaccess <database> <text file with sql commands>. Just be sure your informix environment variables are set properly (INFORMIXSERVER, ONCONFIG).…
onstat -c , no output
Hi, "onstat -c" shows only the first two lines of output. informix online ver ..up 3 days... configuration file ..... The configuration parameters are not outputted.Why does this happen ? (online 7.14 on NCR MP-RAS) TIA Sathish Sadagopan…
Informix Dynamic Server 7.31?
Is any information available regarding the release of IDS 7.31 for Unix? We have Sun E3000 and E4000 machines and are experiencing problems with both 7.30.UC3 and 7.30.UC5 and are curious about 7.31. Thanks. Carleen Avant Naval Safety Center Internet < cavant@safecen.navy.mil …
STRING FUNCTIONS
Are there functions for manipulating varchar type, like upper() or lower() in Informix Online Dynamic Server 7.2? Thanks in advance.…
Netscape Enterprise Connection for Informix Dynamic Server
Hi: Does anyone know the procedure for setting up a Netscape Enterprise Server to connect to an Informix Dynamic server on a remote machine? Michael…
oninit: shared library problem
I'm having problems when initialising the DB using oninit. Config: INFORMIX Dynamic Server Ver 7.23, on a UNISYS-UNIX SVR4. When Initializing, I get the error ...dynamic linker: oninit: symbol not found: gettimeofday The LD_LIBRARY_PATH is set to $INFORMIXDIR/bin and �INFORMIXDIR…
Initi DB
I'm having problems when initialising the DB. Config: INFORMIX Dynamic Server Ver 7.23, on a UNISYS-UNIX SVR4. When Initializing, I get the error ...dynamic linker: oninit: symbol not found: gettimeofday The LD_LIBRARY_PATH is set to $INFORMIXDIR/bin and �INFORMIXDIR/esql help wo…
Index on Informix Online 7.22 ?
I have installed a new Informix Online Dynamic Server 7.22UC3 on our server (HP-UX 10.20). I find it is much much slower than the Informix 7.12 Online DS server if I do not create index for a same program. Why and what is the difference between the two version of Dynamic serv…
Re: esqlvers statement.....results are different on 2 DB servers ???
Tim Jones wrote: > > I've installed Informix 7.30UC3 with the ClientSDK 2.01 software on 2 > servers. Let's call them Server A and B. > > Both A and B had a prior ESQL/C versions. > > After the install, logged in as informix userid on A and ran "esqlvers" > and got this : > I…
esqlvers statement.....results are different on 2 DB servers ???
I've installed Informix 7.30UC3 with the ClientSDK 2.01 software on 2 servers. Let's call them Server A and B. Both A and B had a prior ESQL/C versions. After the install, logged in as informix userid on A and ran "esqlvers" and got this : INFORMIX-ESQL Version 7.22.UC1 …
Decreasing Checkpoint Lengths.
What parameters have the greatest effect on checkpoint lengths? Currenly I have my checkpoint interval at 30 seconds, and a peak times checkpoints are still taking over 10 seconds. We're running multiple configurations on Workgroup Server. Some on WIN NT, Some on SCO, and some…
Informix Dynamic Server Personal Edition
What development apps are known to work with IDS-PE for 95? Infrmx wants to sell me licenses for Dynamic 4gl, esql-c, ddvb for 150usd. Do these work and are there others? 150 sounds ok but the catch is is that the Open-Line Support is outrageous for this (3K usd for unlim. suppor…
Will informix 7.24.uc5 compatiable with solaris 7?
Hi there, I was wondering if Informix Dynamic Server 7.24.uc.5 will be compatiable with solaris 7 when it comes out? Thanks advance, Pat Militzer pmilitzer@ultracom.com…
Re: IECC Server Discovery Failed 2nd
Hi Dale, sorry for not reading your article correctly: Are both agents running admagent and osagent ? If so, when you run stopsa, do both stop? If not, kill them and run startsa again. Is your onconfig still up to date? The agents seem to take all information from onconfig ra…
Informix Online Dynamic Server 7.2.2
When I try to iniailize the shared memory I get an error "oninit: Critical error initializing shared memory" I checked the log and it says the base memory address is 0x80080000 and should be 0x80400000 when I change it it reverses. this is on a SCO open server 5. nay ideas.…
Informix Dynamic Server on Linux NOW!
Check out the Informix WEB Site. There is an announcement that IDS 7.3 is shipping on Linux TODAY! http://www.informix.com/ Art S. Kagel…
Problem installing to NT4.0 server
I'm trying to install Informix dynamic server workgroup edition to Primary domain Nt 4.0 Server. I have created Informix-Admin group and Informix account and grant it all Administrators rights and also Domain administrator rights. The server setup runs ok, but when setup is tryi…
Updating databases
What must be done,eg onconfig, to get the fastest result on updating a database alter tables, inserts etc.…
Deployment Licenses of Informix Dynamic Server
I need a free Deployment Licenses of Informix Dynamic Server!…
Re: Informix Dynamic Server blocks
In article <3609EB18.2AB1B1CD@bull.net>, Helmut Leininger <Helmut.Leininger@bull.net> writes >Hi, > >Sporadically, the Informix server seems to block (every try to connect >or onstat times out and no reaction on onmode -ky). In the MSGPATH I >find the following message: > >09:03:…
ONCONFIG on UNIX
What kind of use if the parameter "SYSALARMPROGRAM" for. And which input parameters are used. Thanks for mailing to baumschlager@pfeiffer.co.at…
Informix Dynamic Server blocks
Hi, Sporadically, the Informix server seems to block (every try to connect or onstat times out and no reaction on onmode -ky). In the MSGPATH I find the following message: 09:03:42 mt.c, line 8362, thread 2139, proc id 17096, mt_notifyvp timed out. Informix server is 7.22.UC2…
Informix Dynamic Server blocks
Hi, Sporadically, the Informix server seems to block (every try to connect or onstat times out and no reaction on onmode -ky). In the MSGPATH I find the following message: 09:03:42 mt.c, line 8362, thread 2139, proc id 17096, mt_notifyvp timed out. Informix server is 7.22.UC2…
Re: Informix Backup ...
In article <6qt48v$8c0$1@news.xmission.com>, craiglanford@yahoo.com (Craig Lanford) wrote: > > > > Your TAPESIZE configuration parameter is larger than the backup device > will hold. This means you will have to either go to two tapes or files > depending on backup method. You al…
Performance-Tuning
Hey FOLKS, we are just beginning to workwith Informix DBMS. One of our main problems is to find the right configuration to the best performance possible. Can anybody give me some advices how to set the parameters in the ONCONFIG-File (We are using Unix aswell as NT). Thank's a …
sizes in onconfig
OWS 7.2 on SCO UNIX: Does anybody know why all sizes of dbspaces or logs, etc. are just half as big as they are in the onconfig file. If I check the size of a dbspace, for example, its file size is 2 GByte, but oncheck -pe says it's 1 GByte. Thanks in advance, Pascal…
Re: OnLine Dynamic Server 7.2 Vs INFORMIX Dynamic Server 7.3
On Tue, 28 Jul 1998 14:40:44 -0500, Ben Jazi <bjazi@fallschurch.esys.com> wrote: >What are the major differences between INFORMIX-OnLine Dynamic Server >7.2 and INFORMIX Dynamic Server 7.3? Is it ORDBMS vs RDMBS? No, IDS 9.x is the ORDBMS. This autumn the 7.3 and 9.x code lin…
Re: OnLine Dynamic Server 7.2 Vs INFORMIX Dynamic Server 7.3
Ben Jazi wrote: > > What are the major differences between INFORMIX-OnLine Dynamic Server > 7.2 and INFORMIX Dynamic Server 7.3? Is it ORDBMS vs RDMBS? > > Thanks, > Ben I don't know the differences in detail but you could check the following pages, where IDS 7.3 is described …
OnLine Dynamic Server 7.2 Vs INFORMIX Dynamic Server 7.3
What are the major differences between INFORMIX-OnLine Dynamic Server 7.2 and INFORMIX Dynamic Server 7.3? Is it ORDBMS vs RDMBS? Thanks, Ben…
Informix computer Base classes
Has any body used the Informix computer base training classes. I am wondering if any of the computer based training classes: "Informix Dynamic Server System Administration" or the "Managing and Optimizing Informix Dynamic Server Databases" is good. Thank You…
Re: Informix Online Dynamic Server 7 on Linux
Piet le Roux wrote: > > If anyone has succeeded to run Informix ODS 7 (SCO) on Linux help would > be appreciated. > I have installed iBCS and the shared libraries and the binaries work, > except that the engine cannot initialize shared memory: Error message > semctl: errno 22…
Informix Online Dynamic Server 7 on Linux
If anyone has succeeded to run Informix ODS 7 (SCO) on Linux help would be appreciated. I have installed iBCS and the shared libraries and the binaries work, except that the engine cannot initialize shared memory: Error message semctl: errno 22 create_vp: cannot allocat m…
Problems with Informix Dynamic Server for NT
Hi Has anyone tried downloading and running the dynamic server product for NT? I have it installed, but get the following error when I boot the system: AdmAgent.exe - Applicatioin error The instruction at "0x10087c69 referenced memory at "0x00000000". The memory could not be r…
Re: Doubt regarding L.Log size
Sadagopan, Sathish wrote: > > Hi, > LOGSIZE in the onconfig is shown as 1000 Kb, whereas size in onstat -l shows > > a figure of 5000 , Page size is 2K. > How can that be ? It looks like someone used onparams to add logfiles with sizes different from that stored in the onconfig.…
Doubt regarding L.Log size
Hi, LOGSIZE in the onconfig is shown as 1000 Kb, whereas size in onstat -l shows a figure of 5000 , Page size is 2K. How can that be ? TIA Sathish…
RE: What are the differences between Informix Dynamic Server
It is confusing! =20 Here's what I know: Prior to renaming: 7.2x =3D ODS 8.0 =3D XPS 9.1 =3D IUS After renaming: 7.2x =3D IDS 8.0 =3D IDS/AD/XP 9.1 =3D IDS/UDO=20 After the 7.3 release: 7.3 =3D IDS 9.1 =3D IDS/UDO After the 8.2 release: 8.0 =3D…
RE: What are the differences between Informix Dynamic Server and
This message is in MIME format. Since your mail reader does not understand this format, some or all of this message may not be legible. ------ =_NextPart_001_01BDA3AF.9242A58C Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable Good quest…
Re: Index for Informix Dynamic Server
William Lai wrote: > > Hello, > > We alreay upgrade our database server from SE5.X to IDS 7.3. After we > convert all the old data to the new server, we have some problems on the > index search. For example, a table: > > table : ith ( ithitno, ithname ), total 1,500,000 records…
Re: Index for Informix Dynamic Server
William Lai <rwie@netvigator.com> offerred: +We alreay upgrade our database server from SE5.X to IDS 7.3. After we +convert all the old data to the new server, we have some problems on the +index search. For example, a table: + +table : ith ( ithitno, ithname ), total 1,500,000…
Index for Informix Dynamic Server
Hello, We alreay upgrade our database server from SE5.X to IDS 7.3. After we convert all the old data to the new server, we have some problems on the index search. For example, a table: table : ith ( ithitno, ithname ), total 1,500,000 records index : ith_1 on ithitno, ithn…
Informix Dynamic Server 7.3
Hello, Since I'm planning a Data Warehouse, I would to do it with the new version of Dynamic Server. Impressions, stability and on which platform? Regards. Fernando _/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/_/ Fernando Collalti Phone: +…
Informix Dynamic Server & Text columns
Hi everybody, Can you help me ? I've created a table with the following structure : column type -------- ---- code smallint obs text How can I insert into this table with Java program ? I'm using Informix Java AP…
Intermittent Problem - error 529 Cannot attach to transaction
We have a HP-UX box (Ver 10.20) running Informix Online Dynamic Server Ver 7.13 and a NT Server (NT4.0) running Informix Online Dynamic Server Ver 7.23. We are trying to access some of the database tables resided in the HP-UX box from the NT Server via synonyms. But we faced inte…
My weird problems
Thanks to all who replied. The Logical Log problem was with memory parameters in the onconfig file. DBSPACETEMP problem still exists however Regards Lee Robertson…
Onconfig Question
I sent this a few weeks ago and didn't get any responses. I am rephrasing the heading and trying again. We are not currently having any performance problems, but I am interested in hearing some opinions from the experts out here. One of our systems is as follows: Sun SPARCcen…
How can I read the header tape of the archive created by ontape?
I have Informix Dynamic Server 7.23.UC1. I would like know the tape header structure created by ontape.…
Re: Upgrading Informix from Online engine to Dynamic Server
Seth Grimes wrote: > > Jane Vohden wrote: > > > > I have been talking with Informix about upgrading our site from the > > 5.xx Online engine to 7.2x Dynamic Server. They said there was no cost > > I don't think that anyone has pointed out the mistaken terminology > h…
What's the difference between ODS 7.22 and 7.23?
What's the difference between Informix Online Dynamic Server version 7.22 and version 7.23? Thanks in advance. Bill Westphal Rodney District Council mis@rodney.govt.nz…
ODBC unix and dynamic SQL
Hi, Can someone give me some help on using informix odbc drivers (unix) with dynamic SQL on Informix-online dynamic server (7.22 unix) when I use "SQLprepare" I receive the message "too many or too few host variables given" but I think all is Ok R. Gueye…
Re: What's the problem with stored procedures
In article <3471B82A.3AC640C0@informix.com>, "Mark D. Stock" <mdstock@informix.com> writes >Oh poohy! You have always been able to change the default value of 50. >It's just that you have to add the configuration parameters to your >configuration file manually. PC_POOLSIZE and PC…
Re: Freeing Logical Log with Status U
What's LOGFILES set to in your onconfig file? Try forcing a checkpoint? Jon.…
Re: Error 208: Shared memory problem
Foster Bass wrote: > > I am using a newly configured Informix install on a RISC running > AIX4.1.2 and every time I try to join mor than three tables in an SQL > statment, I get an error 208. > > I have spent close to 20 hours on the phone with five different tech > support folks…
Next Extent Calc.
Hi, I have INFORMIX-OnLine Dynamic Server Version 7.14.UD2. Does anyone know of a script or program to calculate the next extent size ? Thanks in advance Manuel…
Two Instances on Multiple CPU Machine
Hi , I have a quick couple of questions. We have a SUN machine with SUNOS having 4 CPUs. There is already one instance of Informix(7.2x) up-and-running which uses 2 cpus (1 and 2) by setting AFF_SPROC etc and all other parameters. The second instance of Informix has been config…
Java and Informix Dynamic Server 7.x
Hi friends! I am trying to do server-side java cgi programming to connect to I-ODS 7.x. Do you know how I can do that? I heard it is possible to use the jdbc-odbc bridge( intersolve or openlink's), but the performance is too slow, because of jdbc to odbc and odbc to jdbc convert…
Re: Base address SHMBASE on Axil S/420
Look in the release notes. If what your trying to configure is online 5 or 7 then it will be in something like $INFORMIXDIR/release/ONLINE_7.1 or similar. You'll also find a lot of kernel parameters in here that I'd recommend you double check before you begin. Adam. PS. I hope…
Re: How to set configuration parameters to get maximum performance
Dear Bruce, thank you for your comment. We can't wait for 4 processors, because the machine the company cannot be upgraded to 4 or even more processors. :-( May I ask another question? You wrote that you are using Cobol too. Which compiler do you use (IBM or Micro Focus). Do you…
Re: How to set configuration parameters to get maximum performance
I use RS/6000 (uniprocessors) , Informix 7.11.UC1, RAID 5 disk, and ESQL/Cobol. Although the RAID disk may not be the fastest, it's not that bad, especially if you have write cache. (I don't) What exactly are your problems? My only initial advice is that generally running a 2 C…
Re: How to set configuration parameters to get maximum performance
In article <339A6E9E.BDE55BA0@pop-nidda.de>, Volker Reichel <reichel@pop-nidda.de> writes >Dear all, > >I'm facing a major performance problem with Informix 7.21 on a IBM RS >6000 >two processor machine running AIX 4.1.5 and two RAID 5 subsystems with >4x4 GB each. Informix is pl…
How to set configuration parameters to get maximum performance
Dear all, I'm facing a major performance problem with Informix 7.21 on a IBM RS 6000 two processor machine running AIX 4.1.5 and two RAID 5 subsystems with 4x4 GB each. Informix is placed on machines root device (4 GB mirrored). In addition we have to use Informix ESQL-COBOL API…
Re: Resizing Logical Logs
Also, there is a MAXLOGS parameter in the onconfig file that should be increased. Madison Pruet…
7.1 initialization error
Hi everyone, I have a client that runs 7.1 on a SCO box. When the nettype is set to a shared memory connection (onipcshm) 7.x will not initialize. However, when the nettype is tcpip (ontlitcp) everything works. Do you think this is a Informix configuration problem or a SCO ke…
Re: ONCONFIG
Kerry Davids wrote: > > Jacob Salomon <jake@apparel.net> wrote: > > >Patrick, > > >onconfig.std is meant as a template to copy from. If I had my druthers, > >I would have it shipped with 666 permissions so that even user Informix > >could not (or at least is less likly to) inadv…
Re: ONCONFIG
>From: satriguy@aol.com (SaTriGuy) >Date: 21 Jan 1997 06:01:04 GMT >X-Informix-List-Id: <news.32813> > >If I had my way, I'd remove it from the system all together so that it >would not be possible to 'accidentally' use the wrong onconfig. ;) >Madison Pruet I think the 'it' refe…
Re: ONCONFIG
If I had my way, I'd remove it from the system all together so that it would not be possible to 'accidentally' use the wrong onconfig. ;) Madison Pruet…
Re: ONCONFIG
Jacob Salomon <jake@apparel.net> wrote: >Patrick, >onconfig.std is meant as a template to copy from. If I had my druthers, >I would have it shipped with 666 permissions so that even user nformix >could not (or at least is less likly to) inadvertently modify it. >(Actually, in …
RE: ONCONFIG
Hi Patrick! OK. please check with env command to see the ONCONFIG environment variable, this sould containg the file being use at this moment, and please, make a copy before you make any changes, Regards :) ---------------------------------------------------------------- Mario…
RE: ONCONFIG
You have to check your env variables. One of them is ONCONFIG which will be set to either of the files. Munaf g086mnf@bomplant3.appl.ge.com ---------- From: informix-list-owner[SMTP:informix-list-owner@rmy.emory.edu] Sent: Friday, January 17, 1997 4:04 PM To: informix-list S…
Re: ONCONFIG
In <32DF327E.1DBB@mediacity.com.sg>, Patrick Stacey wrote: }I see 2 onconfig files in my etc directory (sol 2.5.1 platform). } }one has .ifmx and the other .std } }which do I edit in order to change the system configuration? }Specifically I want to configure informix for a multip…
Re: ONCONFIG
Patrick, Type the command "onstat -c | more". This option prints a copy of the current configuration to the screen, but more importantly, the second line gives the path and filename of the current configuation in use. Tracy > > I see 2 onconfig files in my etc directory (sol …
Re: ONCONFIG
If you have to ask this you shouldn't attempt to modify the file. This is RTFM, very much so. You'll depend on knowing so much before tuning OnLine in this way that if you have missed this in the manuals, you may also have missed a lot of other info. Sorry for this. I don't mean …
Re: ONCONFIG
Patrick Stacey wrote: > > I see 2 onconfig files in my etc directory (sol 2.5.1 platform). > > one has .ifmx and the other .std Patrick, onconfig.std is meant as a template to copy from. If I had my druthers, I would have it shipped with 666 permissions so that even user nform…
ONCONFIG
I see 2 onconfig files in my etc directory (sol 2.5.1 platform). one has .ifmx and the other .std which do I edit in order to change the system configuration? Specifically I want to configure informix for a multiprocessor machine (4 CPUs actually). many thanks, /pks -- [ Pat…
Re: Help I'm in crisis
Hi Tony, Check you $ONCONFIG file if the PDQPIORITY > 0, modify it to be 0, that means disable PDQ in $ONCONFIG. Please set PDQPIORITY as user environment variable for large report/ bach job only. Otherwise, every single session takes a lot of memory. Regards Eric Lam Taipei/Tai…
How to use LBU_PRESERVE
Hi, How do I use the configuration parameter LBU_PRESERVE to prevent the logical log full? Can it be used in 7.10.UC1? Coluld anybody help me? Thanks! --------------------------------------------------------------------------- Jerry Tan System Engineer Tatung Co. E-…
Re: onconfig
Hi Sue, >Hi there. I am an Oracle/Sybase dba. I've just been put on a project >which uses Informix Workgroup Server V7.12 on Windows NT. I have no >training or manuals in either Informix or NT, so this question may >appear to come from a simpleton. Stop right there. Go and fin…
Re: onconfig
> From: Sue Alsbury <salsbury@mdshealth.com> > Date: Friday, October 18, 1996 4:11 PM > > Hi there. I am an Oracle/Sybase dba. I've just been put on a project > which uses Informix Workgroup Server V7.12 on Windows NT. I have no > training or manuals in either Informix or NT, so …
Re: onconfig
In article <3267E47A.54DA@mdshealth.com>, Sue Alsbury <salsbury@mdshealth.com> writes >Hi there. I am an Oracle/Sybase dba. I've just been put on a project >which uses Informix Workgroup Server V7.12 on Windows NT. I have no >training or manuals in either Informix or NT, so this …
onconfig
Hi there. I am an Oracle/Sybase dba. I've just been put on a project which uses Informix Workgroup Server V7.12 on Windows NT. I have no training or manuals in either Informix or NT, so this question may appear to come from a simpleton. I issue a select * from tablename. The tab…
fet_buf_size
Hello, Can someone tell me what FET_BUF_SIZE actually is and what it does? Is this a kernel parameter or part of the onconfig file? It's not in my onconfig file and not part of a configurable kernel parameter, but I've been led to believe that it will impact performance. We'r…
Informix Certified Professional Program Update
Informix offers two certification paths. Each path requires the successful completion of two exams. Each exam is US $250 and is between 60-90 minutes long. * Database Specialist for INFORMIX-OnLine Dynamic Server 7.x 111 - Database Fundamentals Exam 112 - Managin…
USERTHREADS etc
rvdbergh@egidius.rug.ac.be (Ria Vandenberghe) asked: >On the SHARED MEMORY parameters screen, a number of parameters are not >shown (e.g. Max # of Userthreads, Max # of Transactions, ...), although we >set these parameters manually in the ONCONFIG configuration file (and >reinit…
Re: Setting shared-mem. conf. params
In article <47vgql$gik@infoserv.rug.ac.be>, rvdbergh@egidius.rug.ac.be (Ria Vandenberghe) wrote: >On the SHARED MEMORY parameters screen, a number of parameters are not >shown (e.g. Max # of Userthreads, Max # of Transactions, ...), although we >set these parameters manually i…
USERTHREADS in 7.10.UD1
rvdbergh@egidius.rug.ac.be (Ria Vandenberghe) asked: >On the SHARED MEMORY parameters screen, a number of parameters are not >shown (e.g. Max # of Userthreads, Max # of Transactions, ...), although we >set these parameters manually in the ONCONFIG configuration file (and >reinit…
Setting shared-mem. conf. params
On the SHARED MEMORY parameters screen, a number of parameters are not shown (e.g. Max # of Userthreads, Max # of Transactions, ...), although we set these parameters manually in the ONCONFIG configuration file (and reinitialized shared memory). Now we cannot check whether our ch…
INFORMIX Tunable Parameters?
Hi, We are trying to configure a 7.10.UD1 server on HP-UX 9.07. We are experiencing problems in tuning the parameters as suggested in the manual esp. the SHMMAX value of 805306367... The max allowed by SAM is 804257792... Has anyone experienced this problem before? Please resp…
Re: INFORMIX-Online Dynamic Server intallation
copy the standard onconfig file and make as few changes as possible to the different parameters. after you are sure you can bring informix online, should you begin to make changes to the onconfig parameters. Use ONMONITOR to make the changes. It will protect you from many mista…
INFORMIX-Online Dynamic Server intallation
I'm about to install INFORMIX-Online Dynamic Server V.7.1 on a SPARC 1000. Has anyone installed this database on a sparc before? If yes...do you have any suggestions or could you give me any advice on certain aspects of the installation you felt might be important to take notice?…
Re: INFORMIX-ONLINE 6 HELP
>I'm trying to follow the instructions in the Admin Guide Vol 1 >to 'Configure a Learning Environment' but keep getting the message >'Shared Memory not initialised for INFORMIXSERVER 'learn_online'. >I'm running SCO Unix on a 32M machine. >Any ideas ? Check to see whether your…
Process Priority with onilne 4.10
Does Online ver 4.10 have fixed priority support like ver 7.0 does with the NOAGE onconfig param. Thanks Chris…
DBMS Server Hardware Selection Parameters
Hello netters, Which factors should be taken into account in selecting a a hardware configuration for running a DBMS software? How can we determine the parameters for that hardware configuration such as the processing power (MIPS, MFLOPS, Memory disk access parameters etc.)? A…
hardware configuration metrics for a DB
This is for Dr.U.Gudukbay of Bilkent University sorry to take your time.... --- F.Polat ............................................ Hello netters, Which factors should be taken into account in selecting a a hardware configuration for running a DBMS software? How can we deter…